beautypg.com

Inst, Gas line size – AquaStar 80 VPS User Manual

Page 27

background image

27

INST

INST

INST

INST

INSTA L L A

A L L A

A L L A

A L L A

A L L ATION CHECKLIST

TION CHECKLIST

TION CHECKLIST

TION CHECKLIST

TION CHECKLIST

Gas Line Size*

For installation on well systems, insure that your water pressure is
between 30 - 50 psi.

Semi-rigid Tubing

1/2"

5/8"

3/4"

7/8"

Liquid Propane

Natural Gas

Model 80

25"

100'

150'

170

NR

25'

80'

Model 80

15'

50'

100'

125

NR

20'

50'

100'

170

NR

NR

35'

70'

*Flex tubing greatly reduces capacity and, therefore, is not recommended.

Minimum Vent Size* and Height

Model

Min. Diameter

Min. Height

Alternative

*WARNING: Vent size must not be restricted. Installation must comply with

national and local codes.

80

4"

10'

6' with 5" vent

125

5"

10'

6' with 6" vent

170

6"

10'

6' with 7" vent

Water Pressure

125

NR

40'

125'

Nominal Iron Pipe Size*