beautypg.com

Troubleshooting – American Dryer Corp. AD-230 User Manual

Page 40

background image

36

SECTION VIII

TROUBLESHOOTING

IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY

and THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE

REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR

CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY

EQUIPMENT per OSHA (Occupational Safety and Health Administration)

STANDARDS.

The information provided will help isolate the most probable component(s) associated with the difficulty

described. The experienced technician realizes, however, that a loose connection or broken/ shorted wire may be

at fault where electrical components are concerned ... and not necessarily the suspected component itself.

Electrical parts should always be checked for failure before being returned to the factory.

The information provided should not be misconstrued as a handbook for use by an untrained person making

repairs.

IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the fuse

being replaced.

WARNING: ALL SERVICE and TROUBLESHOOTING SHOULD BE PERFORMED BY A

QUALIFIED PROFESSIONAL OR SERVICE AGENCY.

WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS

DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.

A. No L.E.D. Display ...

1. Service panel fuse blown or tripped breaker.

2. Blown control circuit fuse (3AG 1/2-Amp [Slo Blo] Fuse)..

3. Failed microprocessor controller (computer).

B. Basket (tumbler) motor does not start, microprocessor controller (computer) shows drying cycle

in progress and L.E.D. motor indicator dot is on ...

1. Microprocessor controller (computer) indicator is on ...

a. Failed motor contactor (relay).

b. Failed motor.