Setup menu – Aprilaire 8800 UNIVERSAL User Manual

Page 22

background image

22

USER SySTEM SETTINGS TAblE

(CONTINUED)

SETUp MENU

System setting

Description

factory default setting (bold) and setting range

LoCkoUT TyPE

Level of lockout (only

available if Security is

enabled)

Off: No lockout

PARTIAL lockout

FULL lockout

MoDE LoCkoUT

System mode lockout

setting (only available in

partial lockout)

Off: No lockout

FULL: no system mode changes allowed

FAn LoCkoUT

Fan mode lockout setting

(only available in partial

lockout)

Off: No lockout

TiMED: changes revert after temporary change period

FULL: no fan mode changes allowed

SETPOINT LOCKOUT

Setpoint lockout setting

(only available in partial

lockout)

Off: No lockout

TiME-LiMiTED: changes revert after temporary change period

RAngE-LiMiTED: set by max setpoint lockout

TiME AnD RAngE: set by max setpoint lockout and temporary change period

FULL: no setpoint changes allowed

MAX SETPoinT

CHANGE IN LOCKOUT

Setpoint range limit

for temperature and

humidity adjustments

(only available in partial

lockout)

±5° f or C, ±5% RH

oFF to ±20° F or C, oFF to ±20% RH

TEMPoRARy CHAngE

PERioD

Time-limited lockout

temporary change period

(only available in partial

lockout)

60 MINUTES

0 to 255 MINUTES