Programming – Aprilaire 8800 UNIVERSAL User Manual
Page 14
14
UNDERSTANDING pROGRAM SCHEDUlES
(CONTINUED)
pROGRAMMING
optionally, the thermostat can be set to a two event or commercial schedule. (See Setup Menu on page 20.)
Event designator
Start time
Set temperature
fan
Heat
Cool
wAkE/oCCUPiED
6:00AM
70°F (21°C)
78°F (26°C)
AUTO
LEAVE/UnoCCUPiED
10:00PM
62°F (17°C)
82°F (28°C)
AUTO
pROGRESSIVE RECOVERy
The Progressive Recovery feature allows the thermostat to activate the heating and cooling equipment prior to an
event in order to reach the desired temperature at the start of the next scheduled event .
Example: if the wAkE time is 6 am, and the temperature is 70°, the heat will come on before 6 am, so the
temperature is 70° by the time you wake at 6 am .