beautypg.com

Variety steamer, Troubleshooting (continued) – Antunes, AJ VS-350 User Manual

Page 20

background image

Variety Steamer

20

P/N 1010745 Rev. g 03/06

trOUblesHOOtInG (continued)

problem

prossible cause

corrective action

unit heats but there is little or no

steam produced

and/or

the product requires more

steaming than usual (continued).

improper water pressure to unit.

Verify that a water pressure regulator is

installed and set to 20 - 25 psi.

insufficient or excessive calcium/

mineral buildup on generator sur-

face.

Verify that a thin layer of deposits is

present on the generator surface.

Refer to the Maintenance section of this

manual.

channels, or Rate and shot values

were programmed improperly.

Restore programming to original values

as described in the Programming sec-

tion of this manual and then reprogram

as needed.

black Manifold O-ring is damaged or

missing.

install Manifold O-ring if missing.

Replace if it is damaged.

Low generator setpoint temperature. Verify the setpoint temperature is 375° f

(190° c) to 400° f (204° c).

steam leaks out of the sides of

the black Manifold Plate.

black Manifold O-ring is damaged or

missing.

install Manifold O-ring if missing.

Replace if it is damaged.

black Manifold is difficult to lock

and unlock onto the generator

with the sliding lever.

black Manifold not being removed

and cleaned daily as required.

Remove and clean the black Manifold

daily as described in the Maintenance

section of this manual.

black Manifold O-Ring is damaged

or worn.

Replace black Manifold O-Ring if dam-

aged or worn.

black Manifold O-ring is not being

lubricated daily with Petro gel.

Lubricate the black Manifold O-ring daily

as described in the Maintenance section

of this manual.

generator is dirty.

clean or delime the generator. see the

Maintenance section of this manual for

more information.

unit floods overnight and/or con-

tinues to steam even when in idle

mode.

solenoid valve is being held open by

debris from the building’s water line

piping due to no pre-strainer/filter on

the water line just before the unit.

attempt to flush the debris out of the

valve by rapidly operating the unit on a

number of “single shot” cycles and then

letting the unit rest. if the unit still leaks,

contact your maintenance person or

authorized service agency.

unit is whistling during use.

unit is not being cleaned Daily and/

or properly.

see the Maintenance section of this

manual.