3-wire Power Supply Cord Connection

use where local codes permit connecting cabinet-ground

conductor to neutral wire.

A

B

D

C

E

F

G

A. 3-wire receptacle (NEMA type 10-30R)

B. 3-wire plug

C. Neutral prong

D. Spade terminals with upturned ends

E. 3/4" (19 mm) UL listed strain relief

F. Ring terminals

G. Neutral (white or center wire)

Connect remaining wires

6.

Connect remaining wires to outer terminal block screws.

Tighten screws. Finally, reinsert tab of terminal block cover

into slot of dryer rear panel. Secure cover with hold-down

screw.

now, go to Venting Requirements.

A

F

Connect ground wire (F) (green or bare) of power supply cord

to external ground conductor screw (A). Tighten screw.

5.

Connect ground wire

4.

Connect neutral wire

Connect neutral wire (white or center) (C) of power supply cord

to center, silver-colored terminal block screw (B). Tighten screw.

B

C

5.

Connect remaining wires

Connect remaining wires to outer terminal block screws.

Tighten screws. Finally, reinsert tab of terminal block cover

into slot of dryer rear panel. Secure cover with hold-down

screw.

now, go to Venting Requirements.

Remove center, silver-colored terminal block screw (B).

B

3.

Remove center screw