11

SCHEDULED MAINTENANCE TABLE

(*): For the related procedure, see the Service Manual
(1): or before each start-up
(2): And after the first 8 running-in hours
(3): replace hydraulic oil for the first time after 500 hours, then after 2,000 hours or every year.

Maintenance operation

On delivery

Every 10

hours

Every 50

hours

Every 100

hours

Every 200

hours

Every 400

hours

Battery fluid level check

(1)

Hopper lifting hydraulic system oil level check

(1)

Motor-to-main broom belt visual inspection and
tension check

(*)

Skirt height and operation check

Side and main broom height check

Frame dust filter cleaning and integrity check

Closed pocket filter cleaning and integrity
check

Filter-shaker operation check

(*)

Brake adjustment

(*)

Nut and screw tightening check

(*) (2)

Drive wheel gearing chain tension check and
cleaning

(*)

Steering chain cleaning

(*)

Vacuum hose integrity check

(*)

Pulley-to-main broom belt replacement

(*)

Motor-to-main broom pulley V-belt
replacement

(*)

Hopper gasket integrity check

(*)

Hopper lifted position control microswitch
adjustment check

(*)

Hopper horizontal position control micro-switch
adjustment check

(*)

Motor carbon brush check and replacement

(*)

Hydraulic oil change

(*) (3)