INSTALLATION INSTRUCTIONS

Connecting gas dryers

w

WARNINg

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

electrical requirements for gas models only

w

WARNINg

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not, under any circumstances, cut or remove the third

(ground) prong from the power cord. Failure to follow this

warning can result in fire, explosion, or death.

For personal safety, this dryer must be properly grounded.

Failure to follow this warning can result in fire, explosion, or death.

The power cord of this dryer is equipped with a 3-prong

(grounding) plug which mates with a standard 3-prong

(grounding) wall outlet to minimize the possibility of electric

shock hazard from this appliance. Failure to follow this warning

can result in fire, explosion, or death.

This dryer must be plugged into a 60 Hz, 120 VAC, grounded

outlet protected by a 15-ampere fuse or circuit breaker. Failure

to follow this warning can result in fire, explosion, or death.

Where a standard 2-prong wall outlet is encountered, it is your

personal responsibility and obligation to have it replaced with

a properly grounded 3-prong wall outlet. Failure to follow this

warning can result in fire, explosion, or death.

Gas supply requirements:

As shipped from the factory, this dryer is configured for use

with natural gas. It can be converted for use with LP (Liquefied

Propane) gas. Gas pressure must not exceed 13 inches of

water column.

A qualified service or gas company technician must connect

the dryer to the gas service.

Failure to do so can result in fire, explosion, or death.

Isolate the dryer from the gas supply system by closing its

individual manual shutoff valve during any pressure testing

of the gas supply. Failure to do so can result in fire, explosion, or

death.

Supply line requirements:

Your laundry room must have a rigid gas supply line to your

dryer. In the United States, an individual manual shutoff valve

MUST be installed within at least 6 ft. (1.8 m) of the dryer, in

accordance with the National Fuel Gas Code ANSI Z223.1 or

Canadian gas installation code CSA B149.1. A

1

⁄₈ - inch NPT

pipe plug must be installed. Failure to do so can result in fire,

explosion, or death

If using a rigid pipe, the rigid pipe should be ½ - inch IPS.

If acceptable under local codes and ordinances and when

acceptable to your gas supplier,

3

⁄₈ - inch approved tubing

may be used where lengths are less than 20 ft. (6.1 m). Larger

tubing should be used for lengths in excess of 20 ft. (6.1 m).

Failure to do so can result in fire, explosion, or death.

Connect the dryer to the type of gas shown on the nameplate.

Failure to do so can result in fire, explosion, or death.

To prevent contamination of the gas valve, purge the gas

supply of air and sediment before connecting the gas supply

to the dryer. Before tightening the connection between the

gas supply and the dryer, purge remaining air until the odor

of gas is detected. Failure to do so can result in fire, explosion, or

death.

DO NOT use an open flame to inspect for gas leaks. Use a

noncorrosive leak-detection fluid. Failure to do so can result in

fire, explosion, or death.

Use only a new AGA- or CSA-certified gas supply line with

flexible stainless steel connectors. Failure to do so can result in

fire, explosion, or death.

Securely tighten all gas connections. Failure to do so can result

in fire, explosion, or death.

DO NOT attempt any disassembly of the dryer; any

disassembly requires the attention and tools of an authorized

and qualified service person or company. Failure to do so can

result in fire, explosion, or death.

Use a pipe-joint compound that is insoluble in Liquefied

Petroleum (LP) gas on all pipe threads. Failure to do so can

result in fire, explosion, or death.