Communication parameters, Command reference list – LG 50LS4000 User Manual
Page 75
ENGLISH
75
EXTERNAL CONTROL DEVICE SETUP
Communication Parameters
y
y
Baud rate: 9600 bps (UART)
y
y
Data length: 8 bits
y
y
Parity : None
y
y
Stop bit: 1 bit
y
y
Communication code: ASCII code
y
y
Use a crossed (reverse) cable.
Command reference list
COMMAND1
COMMAND2
DATA
(Hexadecimal)
COMMAND1
COMMAND2
DATA
(Hexadecimal)
01. Power
k
a
00 - 01
12. OSD Select k
l
00 - 01
02. Input Select x
b
13. Remote
Control
Lock Mode
k
m
00 - 01
03. Aspect
Ratio
k
c
14. Treble
k
r
00 - 64
04. Screen
Mute
k
d
00 - 01
15. Bass
k
s
00 - 64
05. Volume
Mute
k
e
00 - 01
16. Balance
k
t
00 - 64
06. Volume
Control
k
f
00 - 64
17. Color
Temperature
x
u
00 - 64
07. Contrast
k
g
00 - 64
18. Energy
Saving
j
q
08. Brightness
k
h
00 - 64
19. Auto
Configuration
j
u
09. Color
k
i
00 - 64
20. Channel
Add/Del
m
b
00 - 01
10. Tint
k
j
00 - 64
21. Key
m
c
11. Sharpness
k
k
00 - 64
22. Backlight
m
g
00 - 64
COMMAND1 COMMAND2
DATA00
(Hexadecimal)
DATA01
(Hexadecimal)
DATA02
(Hexadecimal)
DATA03
(Hexadecimal)
DATA04
(Hexadecimal)
DATA05
(Hexadecimal)
23. Channel
Tuning
m
a
physical
program
high
major
program
low
major low
minor high minor low
attribute