beautypg.com

Troubleshooting – ATEN CS-1004 User Manual

Page 28

background image

Troubleshooting

Symptom

Possible Cause

Action

Pressing the

HotKeys gets no
response under
OSD.

DIP Switch 6 is set

to OFF.

Make sure that DIP Switch 6 is set to ON.

Pressing Hot

Keys gets no
response.

The connection

from the selected
port to the target
computer has been
broken, or the PC is
turned OFF.

Check the Online LED for the selected port. If it

is not lit:
1. Manually press one of the Select switches to

connect to a computer that is powered ON.

2. Check the cables to make sure they are all

properly connected.

Improper keyboard

reset.

1.

Reset the keyboard (and mouse) by
simultaneously pressing Buttons 1 and 2 on
the First Stage unit for 3 seconds.

2. Unplug the keyboard connector from the

Console Keyboard Port, then plug it back in.

Improper Master

View reset.

Turn off all Master View units and wait five

seconds before turning them back on. See
Powering Off and Restarting, p.12.

Incorrectly keying in

the Port ID.

1.

Be sure to release both Ctrl Keys

simultaneously.
2. After the Ctrl+Ctrl combination, be sure to
key-in the Port ID and press [Enter] within six

seconds.

Mouse not

responding.

Improper mouse

reset.

1.

Reset the mouse (and keyboard) by
simultaneously pressing Buttons 1 and 2 on
the First Stage unit for 3 seconds.

2. Unplug the mouse connector from the

Console Mouse Port, then plug it back in.

Port LEDs 1-4

flash repeatedly

Power On Self Test

problem

See the information on p.7 of this manual

2001-01-13

24

CS-1004 / CS-1008 / CS-1016 User Manual