7 rebuilding the raid, 6 exiting the intel, Matrix storage manager – Asus P7F-M User Manual
Page 126: Rebuilding the raid with other non-raid disk
5-32
Chapter 5: RAID configuration
Select a destination disk with the same size as the original hard disk.
[
DEGRADED VOLUME DETECTED
]
[↑↓]-Previous/Next [ENTER]-Select [ESC]-Exit
"Degraded" volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
X XXXXXXXXXXX XXXXXXXX XX.XGB
5.3.7
Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system
displays the status of the RAID volume as “
Degraded” during POST. You can
rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1.
At the prompt, press
option ROM utility.
2.
If there is a non-RAID SATA Hard Disk available, the utility will prompt to
rebuild the RAID. Press
the destination disk or press
5.3.6
Exiting the Intel
®
Matrix Storage Manager
To exit the utility
1.
From the utility main menu, select
5. Exit, and then press
following warning message appears.
2.
Press
Are you sure you want to exit? (Y/N):
[
CONFIRM EXIT
]