Anti-tip block, Normal installation steps – Bosch HMD8451UC User Manual
Page 6
English 6
Flush Installation Dimensions and Clearances
Figure 4
Figures 2, 3 and 4 contain many Drawer Microwave measure-
ments for reference when planning the drawer’s location.
This Drawer Microwave can be installed below any electric or
gas wall oven.
NOTICE:
Always allow sufficient power cord length to the
electrical outlet to prevent tension.
Always check electrical codes for requirements.
23
1
/
2
"
(597 mm)
21
7
/
8
"
(555 mm)
Base min.
depth
27"
(686 mm)
1"
(25 mm)
1"
(25 mm)
36"
(914 mm)
24
3
/
16
"
(614 mm)
22
1
/
8
"
(562 mm)
Frontview cut out
Cleat
14
5
/
8
" (371 mm)
16
5
/
8
"
(422 mm)
cutout
6" (152 mm)
4" (102 mm)
5" (127 mm)
2
1
/
4
" (57 mm)
1
5
/
8
"
(41 mm)
1
/
2
"
(13 mm)
visible
area
1
/
4
"
(6 mm)
base
thickness
* Suggested location of electrical outlet
** Anti-Tip Block
*** Base should support up to 100 lbs
**** Sides should be finished and extend back to cleat.
Cleats should also be finished, as they may be
visible after installation.
(Cleats are not included with unit.)
*
**
***
****
Anti-Tip Block
Normal Installation Steps
Anti-Tip Block Installation Instructions
The anti-tip block reduces the risk of drawer tipping when
installed properly. Install the anti-tip block 14
13
/
16
inches
above the installation opening floor (where the unit will
sit) for a standard installation or 14
5
/
8
inches for a flush
installation. See Figure
3 (standard installation)
or Figure 4 (flush instal-
lation) and Figure 5.
The 6-inch anti-tip block
must be provided by the
installer.
If the Drawer Microwave
is ever moved to a
different location, the
anti-tip block must also
be moved and installed.
If the anti-tip block is to be anchored to the wall make cer-
tain that the screws holding it penetrate into the structural
members (studs) behind any covering such as drywall.
The anti-tip block prevents serious injury that might result
from spilled hot liquids.
CAUTION
Make sure that the screws do not contact any
wiring or plumbing that may be present in the wall.
WARNING
The unit can tip and cause spills and potential burns
or other injuries if the anti-tip block is not installed
correctly.
Figure 5
4"
5"
Suggested electrical
outlet location*
Anti-Tip
block
6"
3
1
/
2
"