beautypg.com

Anti-tip block, Normal installation steps – Bosch HMD8451UC User Manual

Page 6

background image

English 6

Flush Installation Dimensions and Clearances

Figure 4

Figures 2, 3 and 4 contain many Drawer Microwave measure-

ments for reference when planning the drawer’s location.
This Drawer Microwave can be installed below any electric or

gas wall oven.

NOTICE:

Always allow sufficient power cord length to the

electrical outlet to prevent tension.

Always check electrical codes for requirements.

23

1

/

2

"

(597 mm)

21

7

/

8

"

(555 mm)

Base min.

depth

27"

(686 mm)

1"

(25 mm)

1"

(25 mm)

36"

(914 mm)

24

3

/

16

"

(614 mm)

22

1

/

8

"

(562 mm)

Frontview cut out

Cleat

14

5

/

8

" (371 mm)

16

5

/

8

"

(422 mm)

cutout

6" (152 mm)

4" (102 mm)

5" (127 mm)

2

1

/

4

" (57 mm)

1

5

/

8

"

(41 mm)

1

/

2

"

(13 mm)

visible

area

1

/

4

"

(6 mm)

base

thickness

* Suggested location of electrical outlet

** Anti-Tip Block

*** Base should support up to 100 lbs

**** Sides should be finished and extend back to cleat.

Cleats should also be finished, as they may be

visible after installation.

(Cleats are not included with unit.)

*

**

***

****

Anti-Tip Block

Normal Installation Steps

Anti-Tip Block Installation Instructions
The anti-tip block reduces the risk of drawer tipping when

installed properly. Install the anti-tip block 14

13

/

16

inches

above the installation opening floor (where the unit will

sit) for a standard installation or 14

5

/

8

inches for a flush

installation. See Figure

3 (standard installation)

or Figure 4 (flush instal-

lation) and Figure 5.

The 6-inch anti-tip block

must be provided by the

installer.
If the Drawer Microwave

is ever moved to a

different location, the

anti-tip block must also

be moved and installed.

If the anti-tip block is to be anchored to the wall make cer-

tain that the screws holding it penetrate into the structural

members (studs) behind any covering such as drywall.
The anti-tip block prevents serious injury that might result

from spilled hot liquids.

CAUTION

Make sure that the screws do not contact any

wiring or plumbing that may be present in the wall.

WARNING

The unit can tip and cause spills and potential burns

or other injuries if the anti-tip block is not installed

correctly.

Figure 5

4"

5"

Suggested electrical

outlet location*

Anti-Tip

block

6"

3

1

/

2

"