Remove the recirculation module, Secure connections with clamps, Connect electrical supply – Bosch HCB50651UC User Manual
Page 11: 9 warning, Risk of electric shock
11
Mounting the recirculation model (only for
circulating-air mode)
1.
Use 4 screws (4x8 mm) to screw the housing for the
recirculation module to the angle bracket.
2.
Measure the distance (x) between the lower edge of
the housing for the recirculation module and the lower
edge of the back-pressure flap.
3.
Shorten the exhaust air pipe to the length measured.
4.
Remove the recirculation module.
5.
Push the exhaust air pipe onto the bottom of the
recirculation module.
6.
Position the recirculation module with exhaust air pipe
over the air extraction duct of the extractor hood.
7.
Use 4 screws to fasten the recirculation module to the
angle bracket.
8.
Secure connections with clamps.
Connect Electrical Supply
9
WARNING
RISK OF ELECTRIC SHOCK
Before wiring the appliance, interrupt the main
electrical circuit at the electrical control cabinet. A
circuit with 120 VAC, 15 or 20 Ampere is required.
Grounding notes: this appliance is equipped with a
distributor box with 3 cables. Use the green-yellow
cable for grounding the appliance. Connect the
green-yellow cable to the grounding cable on the
house connection to prevent electric sthock. Do not
under any circumstances damage or remove the
green-yellow cable. Non-adherence can cause
deadly injuries or electric shock.
1.
Remove the left cable passage and the cover of the
motor controller. Fasten the connecting piece for the
installation pipe (listed in cULUS) to the cable
passage.
2.
Connect 1/2" (12.7 mm) installation pipe to motor
controller.
A
Screws
B
Recirculation module
C
Angle bracket
A
Recirculation module
B
Clamps
C
Flue duct
D
Exhaust air duct
$
%
&
$
[
%
&
'
A
Cable passage
B
Cover of the motor controller
A
Installation pipe
B
Power connection
C
Cable connector listed in UL
$
%
$
%
&