beautypg.com

Troubleshooting – Electrolux EL8807A User Manual

Page 12

background image

PROBLEM

POSSIBLE CAUSES

SOLUTION

Motor will not start or suddenly stops

Unit not connected to power source

• Push plug securely into outlet
• Try another outlet or check circuit breaker
• Check plug and cord for damage

Switch not turned on

• Press power switch to ‘carpet’ or ‘bare floor’ setting

Themal cut-off has operated

• Correct the cause of motor overheating. See thermal cut-off information

No suction. Vacuum cleaner does not pick

up lint or dirt

Blockage in air path

• Remove any obstructions that restrict airflow through hose and valve

clean out areas #1 & #2

Dust cup full

• Empty dust cup

Dust Cup Filter clogged

• Remove and clean filter.

Fine dust can block the airflow through the filter and reduce suction even

if dust cup does not look full

Hepa Filter clogged

• Remove and clean filter

Dust Cup Filter not in place

• Filter must be in filter frame for correct performance
• Make sure filter frame is installed properly in filter cover for dust cup as-

sembly to fit back into place

Switch not on proper setting

• Use ‘carpet’ setting for carpetted floors
• Use ‘bare floor’ setting for hard-surfaced floors and when using acces-

sories

* Turbo nozzle clogged (selected models only)

• Remove and clean debris from turbo nozzle

Dust cup will not lock into vacuum cleaner

Dust Cup Filter not in place

• Locate dust cup filter and insert into dust cup

Quick Release handle will not lock into

vacuum cleaner

Telescopic wand is extended

• Place end of wand into opening at back of vacuum and align ribs into

grooves

Red “check brush roll” indicator light is on

Object caught in brush roll

• Unplug vacuum, remove debris and threads from brush roll. Depress

brush roll reset button, plug in unit, and continue.

• Use ‘bare floor’ setting when vacuuming fringe of rugs
• Check brush roll for threads and debris. Clean if needed

Brush roll not positioned properly

• Make sure both ends of brush roll are free of debris and secured properly

so roll can rotate freely

Brush roll not operating properly

Note: ”Check brush roll” indicator light turns

on when brush roll is not turning. Brush roll

motor will shut off to prevent damage to motor.

Brushroll Clean™ will not work when pedal

is engaged

If used for more than 20 seconds consecutively or

concurrently within a short period, ShearClean will

need approximately 1 minute to reset

• Do not use Brush Roll Clean™ for one minute. Feature should then return

to normal function

Brushroll will not turn

Using brushroll clean pedal on high pile rug/carpet

• Move unit to bare floor, push reset button. Operate normally

TROUBLESHOOTING

For your safety, turn vacuum cleaner off and unplug power cord before

attempting to resolve problems.

Note: Any servicing of the vacuum other than described in this manual shall only be performed by an authorized service representative.