Water Quality and Scale

A complete water analysis and an understanding of system requirements are needed to protect the
tankless water heaters and water heating systems from scale. Water analysis shows whether
water is hard or soft. Hard water, unless treated, will cause scaling or liming of the heat exchanger.
The rate of scaling increases with temperature and usage because calcium carbonate and other
scaling compounds lose solubility (fall out of solution) at higher temperatures.

For example, for every

20°F over 140°F, the rate of scale increases by a factor

of 2 (See figure below). Reference target

water quality levels found in the operation / installation manual and consider water treatment if these
levels are exceeded. *