T-d2-in, Flow rate vs. temperature rise pressure loss – Takagi T-D2-IN/OS User Manual

Page 2

background image

T-D2-IN

The Manufacturer reserves the right to change or discontinue the design, drawing and/or specification of its products without notice at any time.

Flow Rate vs. Temperature Rise

Pressure Loss

Flo

w R

at

e (g

pm)

Temperature Rise (

°

F)

Pr

essur

e L

oss (psi)

Head F

eet

Installation Type
Electric Consumption
Fuel

NG

LP

Min 11,000 BTU/h

Min 11,000 BTU/h

Max 199,000 BTU/h

Max 199,000 BTU/h

Energy Factor

0.83

0.82

Min 5.0" W.C.

Min 8.0" W.C.

Max 10.5" W.C.

Max 14.0" W.C.

Flow Rate

Max 10.0 GPM

40 psi or above recommended for maximum flow

Without Remote (Dipswitch Setting) 104°F, 113°F, 122°F (Default), 131°F, 140°F, 158°F,

176°F, and 185°F

With TM-RE30 Temperature Remote

Controller : 99°F to 185°F,

122°F Default Factory Setting

99°F, 100°F, 102°F, 104°F, 106°F, 108°F, 109°F, 110°F,
111°F, 113°F, 115°F, 117°F, 122°F (Default), 131°F,
140°F, 158°F, 167°F, 176°F, and 185°F

Temperature Settings

Indoor and Direct Vent Only
120 VAC ; Standby: 0.05 A, Operation: 0.75 A, Freeze-Protection: 0.93 A

Gas Consumption Input

Inlet Gas Pressure

Water Pressure

15-150 psi

Pressure Only Relief Valve Required
(Min 200,000 BTUs. 150 psi)

0

20

40

60

80

100

120

0

10

20

30

40

50

60

70

80

0.0

2.0

4.0

6.0

8.0

10.0

12.0

Set Temperature : 122

°

F & lower

Set Temperature: 131

°

F & higher

Flow Rate (

gpm

)

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

11.0

12.0

0

20

40

60

80

100

120

140