P2 recirculating pump curves - 60 cycle – Sterlco 140 to 6,285 Gallon Pump Tanks User Manual
Page 26

Pump Tanks
Chapter 6: Appendix
26 of 36
Re-circulation Pump Curves and Specifications
PSI
KG/
TOTAL HEAD
FEET
CM
2
P2 RECIRCULATING PUMP CURVES - 60 CYCLE
40
50
60
70
80
90
100
110
20
25
30
35
40
45
1.5
2
2.5
3
100
200
300
400
500
600
700
800
900 1000 1100 1200 1300
500
1000
1500
2000
2500
3000
3500
4000
5000
4500
U.S. GALLONS
PER MINUTE
PER MINUTE
LITERS
1 1/2 HP
3 HP
5 HP
7 1/2 HP
10 HP
15 HP
20 HP
25 HP
30 HP
A0548756
Pump Information
Pump
Final discharge
trim size
ℵ
Pump ship
wt.
Trim ship
wt.
Model IMP. hp kW rpm
inches
lbs. kg lbs.
kg
60 4.6”
1½
1.19
3,500 2”
NPT
60 28 25
12
16 5.2”
3 2.24
3,500 2½”
flange 90 41 50
23
17 5.3125” 5 3.73
3,500 3”
flange 115 53 75
35
103 8.0”
7½
5.59
1,750 4”
flange 275
125 75
35
104 8.0” 10 7.46
1,750 6”
flange 320
146 95
44
95 8.6” 15
11.19
1,750 6”
flange 425
193
120
55
96 8.9” 20
14.92
1,750 6”
flange 510
232
120
55
96 9.37” 25
18.65
1,750 8”
flange 630
287
165
75
96 9.75” 30
22.38
1,750 8”
flange 670
305
165
75
ℵ Weld slip-on flange sent at discharge termination for flanged trim. 2” terminates at valve connection.