beautypg.com

Raytec VARIO w2 User Manual

Page 10

background image

10

www.rayteccctv.com

UK / Europe Tel: +44 (0) 1670 520055

Americas Tel: +1 613 270 9990

Step 3: Set up camera, lens, and illumination

• Check model number to Raytec performance specification to ensure required

distance is achievable;

- Check unit is set to max power

- Check orientation of unit and ensure it is pointing in correct direction

- Check angle of unit (Holographic lens) – Too narrow may cause hot spots

and the aperture of the camera lens to close down. Too wide and there

may be insufficient light on scene and light going where it is not needed.

• Check the LED status indicator – if a flashing red light is visible in programming

mode, please check the input voltage of the unit. The feedback system will respond

differently depending on what mode the unit is in (see below)

Programming mode – (AMBER LED flashes 1 second on/1 second off)

SOLID GREEN - Power Applied

FLASHING GREEN - Remote IR receiver problem

SOLID RED - Internal LED Fault Detected

FLASHING RED - Voltage supply problem detected

(Please note – once the voltage problem has been corrected, the user must disable remote

control set-up or power the unit on and off to stop the red status LED flashing)

SOLID AMBER - Valid command being received, this remains lit for the duration

that the button on the remote is held. After a valid command has been received the

Amber LED will continue to flash

Normal operating mode

SOLID GREEN - Unit powered up and operating normally

FLASHING GREEN - Remote IR receiver problem

SOLID RED - Internal LED fault detected

SOLID AMBER - Voltage supply problem detected

(Please note – once the voltage problem has been corrected, the user must disable remote

control set-up or power the unit on and off to extinguish the AMBER status LED)

This manual is related to the following products: