Prochem Trident Dehumidifier User Manual
Page 17

17
Maintenance
Service Schedule
Power Cord
Daily
Inspect for wear, fraying or cuts.
Filter
Daily
Inspect, vacuum up to 3 times, replace as needed
Coils
Monthly
Inspect, clean when visibly dirty
Heat Exchange Block
Monthly
Inspect, clean with compressed air only when needed.
Condensate Pump
Monthly
Inspect, clean when needed.
Condensate Drip Tray
Monthly
Inspect, clean when needed.
Cleaning Dehumidifier
Do not perform any cleaning operations with the
unit plugged into power.
N'effectuez aucun nettoyage avec l'unité branchée
à la source d'alimentation électrique.
To maximize dehumidifier performance, replace the air
filter often and clean the internal components when
they become dirty.
1.
Unplug unit from power.
2.
Remove drain tube from machine.
3.
Open housing lid, remove air filter.
4.
Remove 4 screws, with hardware and handle.
5.
Remove 5 screws with hardware and back panel.
6.
Remove 4 screws with hardware and condensate
pump panel.
7.
Remove cover, inner fairing and upper housing.
8.
Remove air-to-air heat exchanger block.
9.
Inspect all internal components for debris buildup.
Do not use high pressure water to clean any of the
internal components of the dehumidifier.
N'utilisez pas l'eau à haute pression pour nettoyer
les composants internes du déshumidificateur.
10. If necessary use a foaming refrigerant coil cleaner
to clean the evaporator and condenser.
11. Wash the air-to-air heat exchanger and any other
internal components that have debris buildup with
warm soapy water.
Replace Condensate Pump
The condensate pump removes water that collects in
the reservoir.
1.
Turn off and unplug unit from power.
2.
Remove condensate pump panel.
3.
Disconnect pump hose.
4.
Disconnect pump wiring.
5.
Remove pump bracket and pump.
86352290 Trident LGR Dehumidifier