Prochem Triad Air Mover User Manual
Page 22

22
86333800 TRIAD THRUSTER FAN
Maintenance
Troubleshooting
PROBLEM
CAUSE
SOLUTION
No Power, Nothing Runs
Power cord not plugged in
Plug in cord
Circuit breaker tripped on fan console
Find source of fault, correct, reset breaker
GFCI tripped on fan console
Find source of fault, correct, reset GFCI
Circuit breaker tripped in building
Reset Breaker
Loose wiring connectors
Check wiring, ensure good connection
Faulty circuit Breaker
Replace Breaker
Faulty GFCI
Replace GFCI
Fan Runs but poor air flow
Intake nozzle is blocked
Remove blockage
Exhaust nozzle is blocked
Remove blockage
Fan will not run, but GFCI
outlet has power
Loose wiring connectors
Check wiring, ensure good connection
Faulty switch
Replace switch
Faulty motor capacitor
Replace Capacitor
Faulty fan motor
Replace motor / impeller assembly
GFCI does not have power,
but fan runs
Loose wiring connectors
Check wiring, ensure good connection
Faulty GFCI
Replace GFCI
Light on switch does not
work but fan runs
Loose wiring connectors
Check wiring, ensure good connection
Faulty switch
Replace switch