beautypg.com

NORSTAT Non-Contact Safety Switches User Manual

Page 7

background image

SAFETY CONTROL UNIT

Supply nominal voltage

24Vac/dc (+/- 15 %)

Nominal power consumption

3VA

Safety contacts

2 x NO

Auxiliary contact

1 x NC

Output contact rating (max)

4A/230Vac; 2A/24Vdc(Res.)@Cos=1

Output contact rating (min)

10V/10mA

Output contact fuse rating

AC=5A; DC=2.5A; Quick blow

Drop out time

Deactivation by inputs, 13ms

Internal fuse

100mA Resetable

Internal fuse recovery time

>2 Seconds

Internal switches

Reset Manual / Automatic—Selectable

Max conductor size

1 x 2.5mm stranded with sleeves, 1 x 4mm solid

Installation group (Control unit)

C in accordance with VDE0110

Enclosure protection

Housing IP40, Terminals IP20

Operating temperature

-10C to +55C (85% Humidity max)

Storage temperature

-20C to +60C

Housing material

Polycarbonate Red

Mounting / Fixing

35mm Symmetric DIN Rail

Utilisation category in accordance with EN 60947-4-1
Safety contacts:AC1 at 230 V

Imin:10mA.Imax:4A

Safety contacts:DC1 at 24 V

Imin:10mA.Imax:2A

Air gap creepage in accordance with EN 60947-1

Vibration In Accordance With EN 60068-2-6

Pollution Degree

2

Weight

210g

Overvoltage Category

III

Frequency

10-55Hz

Rated Insulation Voltage

250V

Amplitude

0.35mm

Rated Impulse Withstand Voltage

4.0KV

Simultaneity Channel 1

Simultaneity Channel 2

SAFETY SWITCHES

Operation

Coded Non-contact

Contact Arrangements

2 x N/O + 1 x N/C

Safety Contact Operating Distance

7mm ON / 12mm OFF

Safety Contact Rating

DC: 24Vdc / 400mA

Auxilliary Contact Rating

DC: 24Vdc / 400mA

External Fusing ( When not using SCU-1 )

400mA

Dimensions

See page 6

IP Rating

IP67

Cable Length

100 Metres max

Operating temperature

-10 to +55C

Storeage temperature

-20 to +60C

Mounting

Target to target

Construction

Red ABS Resin Filled or 316 Grade Stainless Steel resin Filled

SAFETY RELATED DATA

PL In accordance with EN ISO 13849-1

PL-e, CAT 4

SIL CL in accordance with EN IEC 62061

SIL 3

PFHd in accordance with EN IEC 62061

3.62 x 10

-09

PFH

4.43 x 10

-09

B10d

2 X 10

6

MTTFd

>100 years

( Based on usage rate of 360 days/year, 24 hours/day, 10 operations/hour

)

Tm(mission time)

20 years

DC

96.5%

SFF

98.2%

TECHNICAL SPECIFICATIONS

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com