beautypg.com

Dwyer 1207a reports – Dwyer 1207A User Manual

Page 4

background image

DWYER 1207A REPORTS

AUTO STORE ~ (stores up to 255 tests)
From the menu select STORE, AUTO STORE, YES.
Set the time interval (in seconds) between logs.
The analyzer starts logging as soon as you exit the menu
and stops when you select STORE, AUTO STORE, NO.

To view the results select STORE, VIEW, then enter the
log number required. Use the rotary dial and line selector
to view the readings as normal. Use scroll up/down to
view other log numbers.

To delete select DEL ALL, YES

TEST 11

DATE 11/01/09
TIME 16:27:32

FUEL NATU GAS

O2 % 9.3
CO2 % 6.6
CO ppm 21
FLUE

°F 148.6

INLT

°F -OC-

NETT

°F 125.8

EFF (N) 92.5
PRS INWG 0.001
LOSSES % 7.5
XAIR % 80.1

CO/CO2 0.003

PRESSURE ~ (stores up to 8 tests)
From the menu select REPORT, PRESSURE, TEST.

Press the

key to zero the pressure sensor.

CONNECT the pressure hose to pressure connection P1.

Press

to start the 1 minute stabilization period.

Press

again to start the 2 minute tightness test.

To view the results select REPORT, PRESSURE, VIEW.

Use scroll

/

to view other log numbers.

To exit press

.To delete select DEL ALL, YES

TIGHTNESS TEST

LOG 05
TIME 15:40 11/01/09

PRS_1 INWG 20.110
PRS_2 INWG 19.998
DURATION MINS 3:00
…………………………………..
Customer

…………………………………..
Appliance

etc.

TEMPERATURE ~ (stores up to 8 tests)
From the menu select REPORT, TEMP, TEST.
CONNECT the thermocouples, “flow” to Tf, “return” to Ti.

Press

once to view readings and once more to log.

To view the results select REPORT, TEMP, VIEW.

Use scroll

/

to view other log numbers.

To exit press

.To delete select DEL ALL, YES

TEMP TEST

LOG 02
TIME 16:37 11/01/09

FLOW

°F 48.3

RETURN

°F 39.7

NETT

°F 8.6

etc.

ROOM CO ~ (stores up to 8 tests)

From the menu select REPORT, ROOM CO, TEST.
The pump will run and the analyzer will log the CO reading
every minute for 15 minutes.

To view the results select REPORT, ROOM CO, VIEW.

Use scroll

/

to view other log numbers.

Use

to view each reading within the ROOM CO TEST.


To exit use rotary switch. To delete select DEL ALL, YES

ROOM CO TEST

LOG 01
TIME 09:20 11/01/09

TEST CO ppm
0 00
1 02
14 02
15 01
MAXIMUM CO 02

etc.

To print a displayed REPORT hold the

key for 2+ seconds.

Stock No: 18745-2