Operating instructions – BrassCraft 110ES Series User Manual
Page 4

IMPORTANT: You must read the safety instructions
for this machine before use.
1 For best results it is recommended that the machine is
positioned within 2 feet of the drain. (see Fig. 1)
2 Loosen the keyless chuck, pull sufficient cable out of the drum
and place the end of the cable as far into the drain as possible.
3 Plug the power cable into the electrical socket and switch the
power on.
4 Switch the drill direction to forward (FOR) and fully depress
the trigger. The cable will begin to turn. Keep one hand on
cable when it is rotating.
5 Pull approximately 5 feet of extra cable from the drum creating
a slight loop of cable between the machine and the inlet. This
should gently be fed into the inlet.
6 Once the obstruction has been cleared, the line should be
washed through with a hose or power washer.
7 To retrieve the cable, pull one or two feet of cable from the inlet
(drain or stack) while running the machine in forward (FOR)
position and push the cable into the drum. Continue this
procedure until the end of the cable is just inside the inlet.
8 Turn off the machine, remove the remaining cable from the inlet
and hand feed it back into the drum. Finally, tighten the chuck
(hand tight).
Warning A: Do not allow the cable to get hung up on the obstruction.
If the cable end gets hung up on an obstruction, stop the motor and
reverse (REV) the drill until the cable becomes free. Once free from
the obstruction, turn motor to the forward (FOR) position and resume
clearance operation.
Warning B: Do not allow cables to become “over-stressed.” Over
stressing cables due to a stubborn obstruction or snag will create
tension in the cable leading to cable damage or an unpredictable
cable reaction. If the cable becomes over-stressed, follow the same
procedure as advised in “Warning A.”
Warning C: Never fully retract the cable from the inlet while it
is rotating.
Note: It is recommended that the cable is continuously flushed
through with clean water as it is being retrieved from the inlet and
again before putting it away.
OPERATING
INSTRUCTIONS
Figure 1