for this machine before use.

1 For best results it is recommended that the machine is

positioned within 2 feet of the drain. (see Fig. 1)

2 Loosen the keyless chuck, pull sufficient cable out of the drum

and place the end of the cable as far into the drain as possible.

3 Plug the power cable into the electrical socket and switch the

power on.

4 Switch the drill direction to forward (FOR) and fully depress

the trigger. The cable will begin to turn. Keep one hand on

cable when it is rotating.

5 Pull approximately 5 feet of extra cable from the drum creating

a slight loop of cable between the machine and the inlet. This

should gently be fed into the inlet.

6 Once the obstruction has been cleared, the line should be

washed through with a hose or power washer.

7 To retrieve the cable, pull one or two feet of cable from the inlet

(drain or stack) while running the machine in forward (FOR)

position and push the cable into the drum. Continue this

procedure until the end of the cable is just inside the inlet.

8 Turn off the machine, remove the remaining cable from the inlet

and hand feed it back into the drum. Finally, tighten the chuck

(hand tight).

Warning A: Do not allow the cable to get hung up on the obstruction.

If the cable end gets hung up on an obstruction, stop the motor and

reverse (REV) the drill until the cable becomes free. Once free from

the obstruction, turn motor to the forward (FOR) position and resume

clearance operation.

Warning B: Do not allow cables to become “over-stressed.” Over

stressing cables due to a stubborn obstruction or snag will create

tension in the cable leading to cable damage or an unpredictable

cable reaction. If the cable becomes over-stressed, follow the same

procedure as advised in “Warning A.”

Warning C: Never fully retract the cable from the inlet while it

is rotating.

Note: It is recommended that the cable is continuously flushed

through with clean water as it is being retrieved from the inlet and

again before putting it away.

OPERATING

INSTRUCTIONS

Figure 1