beautypg.com

AMX IRX-PP38 User Manual

Irx-pp38, Installation guide, Netlinx plasma-proof ir sensor

background image

Installation Guide

IRX-PP38

NetLinx Plasma-Proof IR Sensor

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

03/08

©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

93-0460

REV: B

IRX-PP38 IR Sensor Overview

The IRX-PP38 IR sensor is designed to provide optimum functionality for IR
reception and transfer to high-end devices such as plasma televisions which
sometimes can have issues with other receivers. The IRX-PP38 is compatible
with AMX’s newest NI-700 and NI-900 NetLinx Master Controllers.

IRX-PP38 Plasma-Proof Components

The terminal IR sensor is wired to the main unit via a 34-inch long (2.83 feet)
cable. The main unit provides both an on-board blue LED (to confirm IR
reception) and a 3-pin mini-Phoenix connection used to wire the sensor to the IR
RX (sensor) port on the back of a compatible AMX device (such as the
NI-700/900 Controllers).

FIG. 1 IRX-PP38 connector

Wiring the IRX-PP38 IR Sensor

The maximum wiring distance between the IRX and a target NI Controller (such
as the NI-700 and NI-900) is 200 feet (60.96 meters). FIG. 2 displays a sample
wiring diagram which shows how you can wire a single Controller for
communication to two separate IRX IR sensors.

FIG. 2 Sample wiring diagram between NI Controller and multiple IRX sensors

Installation Overview

Note: Never pre-tin wires for compression-type connections.

1.

Strip 0.25 inch (6.35 mm) of insulation off all wires.

2.

Insert each wire into the appropriate opening on the IRX-PP38 connector
according to the wiring diagrams and connector types described in FIG. 2.
Note: Always match the wiring on each end of these connections. If you
are using a red insulated wire to supply power on one connector, make
sure you thread this same wire into the PWR connector at the other end.

3.

Insert each wire into the appropriate opening on the NI’s rear IR RX
connector, according to the wiring diagrams and connector types described
in FIG. 2.

4.

Tighten the screws to secure the wires into their respective connectors.
Note: Do not tighten the screws excessively. Doing so may strip the
threads and damage the connector.

5.

Remove the cover off the adhesive foam on the IR sensor.

6.

Adhere the adhesive flat side of the terminal plasma-proof IR sensor to any
object within the line of sight of your remote. Make sure the raised oval side
of the terminal IR sensor (opaque) is facing outwards and can receive the
IR signal from the remote (such as a Mio R-1).

FIG. 3 Equipment wiring overview

You can use the IRX-PP38 in any installation where a previous AMX IRX device
was used. For illustration purposes, the NI-900 is used in this document’s wiring
diagrams.

Note: The IRX- PP38 uses the IR input port on an NI-700/900 controller (one
IRX-PP38 per NI-700/900).

IRX-PP38 Specifications

Current Draw:

• 10 mA @ 12VDC

Dimensions
(HWD):

• 0.56" x 3.88" x 1.06" (1.43 cm x 9.84 cm x 2.70 cm)

Features:

• Relies on both optical and electronic filtering to reject

interference from fluorescent lamps and plasma displays.

• Supports an AMX IR frequency of 38 KHz.

Mounting:

• Main unit can either be hidden behind other electronics or

secured to a surface near the target device.

• Maximum wire distance to an NI700/900: 200 feet (60.96

meters)

IR Sensor
Components:

• IR Feedback LED (blue). LED illuminates when it receives an IR

signal.

• 3-pin mini-Phoenix connector. Wires the IRX-PP38 to the IR

receive port on compatible AMX devices.

• Terminal IR sensor. This sensor adheres to any object within the

line of sight of your remote and enables you to receive control
signals from either an IR Emitter or a hand-held remote control.

• Two screw openings. These openings (located at opposite ends

of the main IR sensor) are used to secure the unit. This portion
of the IRX-PP38 is kept out of sight whereas the terminal IR
sensor adheres to the IR window.

Included
Accessories:

• Adhesive foam (pre-installed onto the terminal IR sensor)
• IRX-PP38 Installation Guide (93-0460)
• Two black metal screws (#2 x 3/8”)

34

” (

0.

86

m

)

IR feedback LED (blue)

Wired to
NI-700/900

Terminal
Plasma-proof
IR sensor

20

0

F

e

e

t M

A

X

PWR

GND

IN

AUX

IRX-PP38 #2

IRX-PP38 #1

To the Integrated

Top view

Top view

SIG (signal)

+12 VDC

GND

Controller’s rear

IR RX connector

SIG (signal)

+12 VDC

GND

This connection may

vary among different

compatible AMX devices

Top view

IRX-PP38

Plasma TV

NI Controller

(with IRX port)

Mio R-1