beautypg.com

F.s.s. in action, F.s.s.) – American Dryer Corp. ML-55II User Manual

Page 23

background image

113345-9

www.amdry.com

21

Installation _____________________________

Requirements
The F.S.S. must be supplied with a minimum water pipe size
of 1/2” and be provided with 40 psi +/- 20 psi (2.75 bar +/-
1.37 bar) of pressure. For use of optional manual bypass, a
s e c o n d s o u r c e w i t h t h e s a m e p i p i n g a n d p r e s s u r e
requirements is required.

Flexible 1/2-inch feeds must be provided to avoid damage to
electric water solenoid valve by vibration.

Important

Flexible supply line/coupling must be used. Solenoid

valve failure due to hard plumbing connections will
void warranty.

If the rear area of the dryer, or the water supply is located in an
area where it will be exposed to cold/freezing temperatures,
provisions must be made to protect these water lines from
freezing.

Warning

If the water in the supply line or water solenoid valve

freezes, the F.S.S. will be inoperative!!

Important

Appliance is to be connected to the water mains using

a new hose-set and the old hose-sets should not be
reused.

Water Connections _____________________

The water connection is made to the 3/4”-11.5 NH hose
adapter of the electric water solenoid valve, located at the
rear upper midsection of the dryer (refer to the photo).

The water solenoid valve has a 3/8” M.P.T. connection supplied
with a 3/4”-11.5 NH hose adapter to provide the minimum
1/2-inch supply (feed) line. Flexible supply line/coupling must
be used in an effort to avoid damaging the electric water
solenoid valve.

Note

The 3/4”-11.5 NH is a standard hose coupling screw

thread. It is not to be confused with 3/4” N.P.T. The
sealing of an NH connection is made with a washer

opposed to the mating threads of an N.P.T. assembly. The
two (2) thread designs are not compatible.

Important

Flexible supply line/coupling must be used. Solenoid

valve failure due to hard plumbing connections will
void warranty. It is recommended that a filter or

strainer be installed in the water supply line.

F

IRE

S

UPPRESSION

S

YSTEM

(F.S.S.) _____________________

F.S.S. In Action

The exclusive Fire Suppression System (F.S.S.) will extinguish
fires that may start in the drying basket (tumbler). A series of
sensors positioned throughout the basket (tumbler) and
interfaced with the microprocessor will trigger the F.S.S. water
jet(s) to quickly extinguish the flames. The water jet(s) remain
on for 2 minutes and will automatically activate again if a fire
condition remains or reignites. While the water jet(s) are
activated, the basket (tumbler) will jog to move the water
throughout the load. The microprocessor will display that
the system was activated and will continue to display until
the dryer is attended to.

Before You Start ______________________

Check local codes and permits

Call your local water company or the proper municipal
authority for information regarding local codes.

Important

I t i s y o u r r e s p o n s i b i l i t y t o h a v e a l l p l u m b i n g

connections made by a qualified professional to
ensure that the plumbing installation is adequate

and conforms to local, state, and federal regulations or codes.

It is the installation or owners responsibility to see that the
necessary or required water, water pressure, pipe size, or
connections are provided. Manufacturer assumes no
responsibility if the F.S.S. is not connected, installed, or
maintained properly.

!

!

!

!

!

!