Setting
The DIP switches under the front clear cover are used
for accumulator and timer settings. As the front plate
states, the setting is the sum of the numbered switches
turned on. Any number from one to 127 can be set.
The multiply-by-ten switch must be used for numbers
from 130 to 1,270.
The easiest way to set a number is to begin with the
largest number which is less than the target, then add
smaller numbers until the target is reached. See illus-
tration at right.
Example 1: The desired accumulator count is 12. First
turn on the 8 switch, followed by the 4.
(8 + 4 = 12)
Example 2: The desired time is three minutes (180
seconds). Use 16 and 2 to set 18, then use the multi-
ply-by-ten switch to get 180.
COUNTS
32
16
8
4
2
1
64
32
16
8
4
2
1
SECONDS
64
OFF
ON
T
I
M
E
R
A
C
C
U
M
12 counts
180 seconds
This switch "ON"
multiplies by 10
This switch "ON"
multiplies by 10
Example 1
Example 2
3 of 4
GND
SIGNAL
EXTERNALLY-PACED
METERING PUMP
DRY CONTACT
TYPE METER (MR,WPR)
GND
GND
SIGNAL
SIGNAL
+12 VDC
+12 VDC
PUMP+
SOLID STATE TYPE
METER (ME,IP,WT)
SOLID STATE TYPE
METER (ME,IP,WT)
PT32 CONNECTIONS DIAGRAM
Ground
Signal
Pump
+
5 AMP AGC FUSE
110 VAC
INPUT
110 VAC
OUTPUT
Hot Normally Closed
Hot Normally Open
Neutral
Ground
+ 12 VDC
Neutral
Ground
Hot
PT33 CONNECTIONS DIAGRAM
Hot
Neutral
Ground
High Flow Relay
NC NO N G
NC NO N G
Hot Normally Closed
Hot Normally Open
Neutral
Ground
Ground
Neutral
Hot Normally Open
Hot Normally Closed
110 VAC Input
Low Flow Relay
JP1
For Sequential timer operation,
remove jumper and replace to
connect these two pins.
JP2
JP2
JP1