General information features, Specifications, Flow range – Seametrics EM 101 v.2 User Manual
Page 3

Page 1
The EM101 is a small electromagnetic low-flow flowmeter with
chemically-resistant plastic wetted parts and platinum electrodes
suitable for use with a variety of chemicals. Capable of measur-
ing pulsating flows from diaphragm-type metering pumps, it is
designed primarily for electrically-conductive chemical injection
applications. The 1/4” and 3/8” sizes monitor maximum flows
of 1 and 3 gallons per minute (or 4 and 11 L/min), respectively.
Barb or NPT fittings are available, and must be designated at
time of order.
The EM101 is 115 Vac, 60 Hz powered and includes a rate and
total display as well as a variety of outputs. For continuous trans-
mission of a flow signal, there is a 4-20 mA output, a 0-5 volt signal,
and a frequency signal proportional to flow. In addition, there are
relay alarm outputs for user-set low and high flow levels.
GENERAL INFORMATION
FEATURES
Backlit LCD display
(16 characters x 2 lines)
Captive plastic cover screw (4)
(mounting screws inside)
Display
Flow
Meter
Polycarbonate housing
Power cord
Connector (2)
for optional output cables
Connector (2)
for sensor cables
6 ft. control cables (2)
out to display
10-24 grounding screws
(on bottom of meter)
Removable bracket
for mounting
PVDF plastic fittings (2)
Male NPT or barb
(must be designated at time of order)
Fusion coated
aluminum housing
Keypad switches, tactile
SPECIFICATIONS*
Fusion coated aluminum
Platinum
Viton™ (EPDM optional)
Polycarbonate
Gal/Minute, Liters/Second, Gal/Hour
Gallons, Liters
115 Vac, 60 Hz
+/-1% of reading,
plus .005 gpm (0.02 lpm)
185˚ F (85˚ C)
150 psi (@ 75˚ F)
>20 microSiemens/cm
• 4-20 mA, 0-5 Volts, both isolated
• Frequency to 9999 pulses per gallon, isolated (10 mA, 30 Vdc)
• High alarm, low alarm relay, isolated (100 mA, 110 Vac/Vdc)
Materials Meter housing
Electrodes
O-Ring
Display housing
Rate Display Units
Total Display Units
Power
Accuracy
Max Fluid Temperature
Maximum Pressure
Minimum Conductivity
Outputs
FLOW RANGE
SIZE
LOW FLOW CUTOFF
MINIMUM FLOW for spec accuracy
MAXIMUM FLOW
-025
-038
L/MIN
GAL/MIN
GAL/hR
L/MIN
GAL/MIN
GAL/hR
L/MIN
GAL/MIN
GAL/hR
.04
.01
.60
.26
.07
4.2
3.8
1
60
.11
.03
1.80
.76
0.2
12
11
3
180
*Specifications subject to change • Please consult our website for current data (www.seametrics.com).