Position.
MJ-Series meters should be installed horizontally
with the register up. Vertical mounting will result in some de-
gree of under-measurement and shortened life of the bearings.
No upstream straight pipe is required.
Couplings.
Male NPT threaded couplings are included with
each meter. The threads on the end of the meter are IPS
straight threads one size bigger than the meter size. Though
it is possible to thread a standard pipe coupling directly onto
the meter for close coupling, the included couplings are much
preferable because they provide a union connection for meter
service. Be sure to use the included gasket between the end
of the meter and the coupling.
Connections.
MJE/MJHE and MJR/MJHR sensors are sup-
plied with a color coded output cable (see diagram, page 4).
Optional connectors can be ordered to plug directly into a
Seametrics control or LMI metering pump.
WARNING
DO NOT INSTALL
METER IN OVERHEAD
INDOOR PIPING OR
WHERE LEAKAGE
MAY CAUSE DAMAGE
GENERAL INFORMATION, INSTALLATION and MAINTENANCE
Page 2
GENERAL INFORMATION
MJ-Series meters use the internationally-accepted multi-jet
principle. A gear train drives the register totalizer dials. For
pulse output, one of the pointers is replaced by a magnet
arm, which is detected by an encapsulated sensor attached
to the outside of the lens.
MJE
(cold water) and MJHE (hot water) meters use a solid-
state, long-lasting Hall-effect sensor, which requires power.
They are suited for use with Seametrics controls and metering
pumps (LMI for instance) that have sensor power.
MJR
(cold water) and MJHR (hot water) meters use a reed
switch. They provide a dry contact closure and do not require
power.
MJT
(cold water) and MJHT (hot water) meters do not have a
sensor, and they totalize only.
SPECIFICATIONS*
6 mA at 12 Vdc (MJE/MJHE only)
105˚ F (40˚ C) max
194˚ F (90˚ C) max
150 psi operating
Cast bronze, epoxy powder coated inside and out
Engineered thermoplastic
Alnico
+/- 1.5% of reading
MJE/MJHE
MJR/MJHR MJT/MJHT
Hall-effect
Reed switch Totalizer only
20 mA
20 mA
n/a
24 Vdc
24 Vdc or Vac
n/a
12’ (4 m) standard (2000’ maximum run)
3/4”
1”
1-1/2”
2”
0.22
0.44
0.88
1.98
22
52
88
132
Power
Temperature
Cold Water
Hot Water
Pressure
Materials Body
Internals
Magnet
Accuracy
Pulse Output
Sensor
Max Current
Max Voltage
Cable Length
Flow Rates (GPM)
Minimum
**Maximum
INSTALLATION
Pulse Output.
Both MJE/MJHE and MJR/MJHR sensors
respond to a magnet that rotates on the face of the meter
under the lens. The sensor turns on and off once each time
the magnet passes under it. Sensors are designed for elec-
tronic control loads, and should not be used to switch power
loads or line voltages. See maximum current and voltage
ratings, under Specifications.
MAINTENANCE
Seametrics recommends all service to be performed by an
authorized distributor or the factory to maintain the integrity
of the protective tamper-proof wire-and-seal.
Inlet Strainer.
Clean the strainer yearly, or as required, de-
pending on water condition. Pull out the strainer or backflush
the meter to loosen trapped particulates.
Calibration.
Meters used for billing or billing exemp-
tion may be regulated by state or local authorities. New
meters are factory-tested to meet the AWWA C-708
Multi-Jet Meter accuracy specification. Some states
require retesting at various intervals, typically eight years for
3/4" meters, six for 1", and four for 1-1/2" and 2". Meters
used for control should be tested every 5-10 years. Testing
may be done by a local mobile meter service or in a private
or municipal meter shop. Changes in calibration should be
made at an authorized meter shop.
**CAUTION:
Excessive flow can cause breakage.
Do not exceed recommended maximums.
Caution:
These water meters are
not recommended for installation
in uninsulated suspended ceil-
ings where freezing is possible,
or in any overhead indoor piping
configuration where leakage may
cause damage.