8.0 Appendix

8.1 WATER CHEMISTRY RANGES

(These ranges are in accordance with suggested NSPI
Standards for swimming pools.)

pH: 7.4 -7.6

Alkalinity: Approx. 80-120 ppm ** (parts per million)
Higher levels may be acceptable in areas where it

naturally occurs in the local water supply.

Consult a pool professional in your area.

Cyanuric Acid: 0-50 ppm.

Maintain at 30 ppm or less for best probe life.*

TDS (Total Dissolved Solids): 300 - 2000 ppm
Calcium Hardness: 200-400 ppm
Free Chlorine:
1.0 - 3.0 ppm (> 700 millivolts ORP)

*20-30 ppm of cyanuric acid provides approx. 95% of the shielding effect for chlorine.
**When using tri-chlor, recommended alkalinity is 95-125 ppm.

8.2 Typical System Installations

** FLOWSWITCH

EARTH
GROUND

*** OPTIONAL FILTER TO

HELP KEEP MANIFOLD

AND PROBES CLEAR OF

DEBRIS.

*SAFETY FLOWSWITCH FOR

PROTECTION OF HEATER AND

TO ENSURE DILUTION OF

CHEMICAL INTO POOL.

**SAFETY FLOWSWITCH TO ENSURE
CIRCULATION TO CONTROL PROBES
AND INDICATOR THAT POOL
CIRCULATION IS OCCURRING.

CHLORINE

EARTH
GROUND

HEATER

FILTER

POOL
PUMP

WATER

FROM
POOL

*FLOWSWITCH

***FILTER

WATER
TO

POOL

PUMP

ELECTRICAL
OUTLET
CONTROLLED BY
CIRCULATION

SYSTEM

ORP

CONTROLLER

SYSTEM USING CHLORINE

MANUAL pH CONTROL

MANIFOLD