Installation, Operation – Pyromation Precision Tip Re-Adjustable Melt Bolt Thermocouple User Manual
Page 2
INSTALLATION
B
2 3/4" - 3 3/4"
X
0" - 1"
ADJUSTABLE
1/2" - 20 2A UNF
1/8" GRADUATED MARKINGS
05/32"
3/4" HEX
Removing existing sensor using the following steps:
1. Retract existing sensor to minimum immersion.
2. Allow machine to cool and return to an un-pressurized condition.
3. Remove sensor from machine.
4. Inspect mounting hole to ensure there is no debris or deterioration
of the sealing surface and threads. See Figure 2 below.
Clean and repair as needed.
Install the new sensor using the following steps:
1. Retract the new sensor to minimum immersion.
2. Install sensor into mounting hole.
3. Tighten sensor into machine using the 3/4” hex to 40 foot/pounds.
4. Connect instrument extension leads.
1/2"-20 UNF, 2A
10 THREADS MINIMUM
00.312"-0.318"
0.100" MAX IMPERFECT THREADS
0.250"
31 to 45
OPERATION
The Melt Bolt should be fully retracted during operation start up. When the plastic
reaches a melted state, the melt bolt can be immersed. Turn the adjusting screw
clockwise to extend the tip, turn the screw counter-clockwise to retract the tip. The
graduated markings are spaced at 1/8” intervals allowing for easy repeat sensor
placement. Retract the melt bolt completely before allowing the melt stream to
cool. Forcing the screw may result in damage to the sensor.
Figure 1
Figure 2
Phone (260) 484-2580 • FAX (260) 482-6805 or (800) 837-6805 • www.pyromation.com
2 of 2
Melt-1
© Copyright 2005 Pyromation, Inc., All Rights Reserved.