Specifications for options, Dimensions – Precision Control Systems 930 User Manual
Page 26
Model 930 ControlIR
TM
Instruction Manual
Dimensions and Specifications
Research, Inc.
Page 22 of 25
Specifications for Options
Option Code
Temperature Controller Option
TCT & TCP
Thermocouple type (TCT):
Type ‘K’
Sensor Input (TCP):
4-20mA scaled 0-2500 deg. F
Alarm relay rating:
5A @ 120VAC resistive, 3A @ 240VAC
Sample rate:
10 HZ
Calibration accuracy:
+/- 0.2% of full scale +/- 1 digit
Control modes:
PID or PI, PD, P only, or On/Off
Temperature stability:
5uV/
°C max, 3uV/°C typical
Noise Rejection:
Common Mode > 100 dB, Series Mode > 70 dB
Autotune: Operator
initiated
Option Code
Voltmeter Option
VM
RMS Voltage transducer:
0-600 VAC to 0-5 VDC
Overall accuracy:
+/- 2 VAC
DIMENSIONS
Figure 6-1 Model 930
Dimensions
Overall
Figure 6-1 displays the overall dimensions of the Model 935 power control system.
The dimensions include the side vents and door handle.