beautypg.com

Maintenance, Troubleshooting, Maintenance and trouble shooting – Precision Control Systems 5420 User Manual

Page 13

background image

Model 5420 ControlIR

TM

User Manual

Maintenance








Maintenance




Troubleshooting
































Maintenance and
Trouble Shooting



No routine maintenance is required. The 5420 should be kept clean and
dry. If cleaning is required, unplug unit before cleaning.



Troubleshooting should be done by Qualified Personnel especially if the
5420 needs to be opened up.






SYMPTON

ACTION

Heater will not turn on.

- unit is plugged into an energized receptacle
- on/off switch is in the ‘On’ position.
- On 5420 and 5420E versions with

potentiometer control, verify control is not
set to 0.

- On 5420E make sure the timer is not set to

0 when pressing the green button,
additionally the red LED should be flashing
as the timer counts down.

- Heater properly connected to the 5420.
- Lamp burned out in the heater.
- 480 volt 5420E and 5420mA check fuses.

Heater will not turn off.

- Shorted SCR unit always runs at 100%

power. Can be checked: with unit
unplugged, open unit disconnect heater
wires and put an ohm meter across L1 and
L2 if it reads 0 or a small value, the SCR is
defective.

- On the 5420E check for the correct time

range, and LED flashing.

Research, Inc.

10