NSi Industries P1104FM-M User Manual
P1104fm-m, Installation & wiring instructions, Time switch mechanism for pool panels
MODEL#:
P1104FM-M
240 VOLT, 24-HOUR MECHANICAL TIME SWITCH MECHANISM
w/ Fireman Switch (Heater Cutoff Switch)
CONTACT CONFIGURATION:
DPST (Double Pole Single Throw), (2) NO (Normally Open Contacts),
(1) NC (Normally Closed Contact)
TIME SWITCH RATING:
40A Resistive/Inductive per pole, 7.5HP @ 240V (NO Contacts);
15A General Purpose/Resistive
MODES OF OPERATION:
3 Operating modes available: Timer/AUTO, OFF/Standby, ON
FIREMAN SWITCH RATING:
15A, SPST @ 12OV
AUTOMATIC OPERATION:
Time Switch can be switched on or off in 15 minute increments for a multitude of on/
off operations per 24 hour period. See below for details on “modes of operation”.
IMPORTANT SAFETY INSTRUCTIONS
READ & FOLLOW ALL INSTRUCTIONS – SAVE THESE INSTRUCTIONS
ATTENTION: Read carefully before attempting to install this control. Failure to comply with instructions could result in personal injury and/or property damage!
This control must be installed in accordance with National and Local Electrical Codes.
Disconnect power at main panel before installing or servicing this device.
USE COPPER CONDUCTORS ONLY
Do not exceed the ratings of this device, and current capacity of conductors
This control should not operate any equipment which would cause bodily injury or property damage should it be activate
unexpectedly.
1.
2.
3.
4.
5.
INSTALLATION & WIRING INSTRUCTIONS
To install Time Switch into control panel, insert lower back
edge of mechanism into Universal mounting plate located
in control panel. Push top front edge of mechanism down
into the mounting plate. You will here a click indicating
that the Time Switch is securely attached to universal
mounting plate.
To wire switch follow the wiring diagram provided.
Use solid or stranded COPPER wire only.
Strip the supply and load wires by removing 1/2 inch of
insulation.
Insert the wires under the proper terminal plates and
tighten the screws firmly.
1.
2.
3.
4.
5.
PROGRAMMING & OPERATING YOUR TIME SWITCH MECHANISM
SETTING THE TIME:
Rotate clock face in a clockwise direction until proper time is displayed. In order to properly set time
for AM or PM, verify that black arrow on clock face matches the correct 24-hour clock setting (example: 6=6AM, 18=6PM). If it
does not, rotate clockwise 1 complete turn for correct AM or PM setting.
SETTING “ON” and “OFF” TIMES:
Set the captive trippers for
desired on/off sequence required.
OFF-Push trippers IN (toward center of clock)
ON-Push trippers OUT (away from center of clock)
MODES OF OPERATION:
(Using 3-Position Rocker Switch)
Timer/AUTO: Automatic Time Switch operation according
to captive tripper’s on/off settings
OFF/Standby: Maintains proper clock time and Time Switch
program settings during periods of non-use.
ON: Used to override Timer/AUTO mode. User can turn the
Time Switch ON. Time Switch will remain ON until the user
switches back to TIMER/AUTO or OFF mode.
•
•
•
•
•
TORK, INC. • 888.500.4598 • www.TORK.com
®
TIME SWITCH MECHANISM FOR POOL PANELS
TIMER/AUTO
OFF/STANDBY
ON
MODES
A DIVISION OF
NSi INDUSTRIES, LLC
NOTE: There is no adjustment to fireman switch
E312471