80028042wiring, Tork electromechanical, 24 hour time switches duty cycle dial – NSi Industries 8001 User Manual
Page 3: Mechanical, Tork, 8000 series, Applications, Specifications, Specification writer’s guide, Ordering information

MECHANICAL
TORK ELECTROMECHANICAL
TORK
1 Grove St., Mt. Vernon, NY 10550 • Tel: 914-664-3542 • Fax: 914-664-5052 • Internet: http://www.tork.com
24 HOUR TIME SWITCHES
Duty Cycle Dial
APPLICATIONS
For one to many daily ON-OFF operations
•
Duty Cycling
•
Ventilating Fans
•
Pumping
•
Irrigation
•
Process Control
•
Laboratory Experiments
SPECIFICATIONS
Contact Ratings: 20 Amps at 120 or 240V, 5 Amps at
480V, 3/4 HP at 120V AC
Timing Motor: Heavy duty synchronous, self-starting,
high torque. Power Consumption: 3 watts. Optional
reserve power spring mechanism keeps dial on time up to
16 hours during power outage. Power Consumption: 5
watts. Add suffix L to model number.
Dial: Captivated tabs for setting are easily tilted in or out
by hand. Switch stays ON or OFF as set when adjacent
tabs are set alike. Markings in English, French & Spanish.
1 to 48 ON-OFF operations per day.
96 tabs permit 15 minute switching changes.
Duty Cycles adjustable from 1/2, 1, 2, 3, 4, 6, 12 and 24 hours.
Operating Temperature Range: -40° to +165°F. (-40° to
+74°C.)
Enclosures:
See end of controls section for dimensions.
General purpose (NEMA 1). Drawn steel, beige enamel,
with combination 1/2” and 3/4” K.O.’s on sides, bottom and
back. Lockable hasp. Cover is removable and movement
releases from case at finger touch for easy installation.
Other Mountings:
Model IAP-Intermatic
®
Adapter Plate – allows any TORK
8000 model to fit into an Intermatic case without necessity
of changing the enclosure.
Flush, with lock and key (suffix FL1) – Model 9001*
Duplex – 2 standard units in one indoor/outdoor metal
case, (except 3 pole) surface (suffix DUOL) – Model 9004L*
Noryl
®
Indoor/Outdoor– NEMA 3R (suffix N) – Model
9000N.* (Not available for 8007, 8007L, 8008, 8008L,
8007V, 8007VL)
Metal Indoor/Outdoor – NEMA 3 (suffix O) – Model
9000A* (hinged side)
Bracket mounting – specify mechanism only, with bracket.
*Use model number when ordering special enclosures separately.
SPECIFICATION WRITER’S GUIDE
The time switches shall be of duty cycle type, capable of programming at
15-minute intervals of the day. Schedule tabs shall be captive on the dial,
and shall be easily set by hand without tools to obtain or to change the
desired schedule. The switching condition shall be maintained when adja-
cent tabs are set alike. The unit shall be powered by a self-starting enclosed
120 (or 208-277) volt synchronous motor capable of continuous accurate
operation. The switch mechanism shall be a self-contained unit rated at not
less than 20 amps, 120 volts, single pole, double throw, and shall be readily
replaceable in the field.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model
8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as
an integral part of the time switch, to enable the switching operation to be
skipped for any preselected day or days of the week. The time switch shall
be similar and equal to Tork Model 8007 or (8007V.) FOR 8007L ADD:
(Same description as for 8007). The unit shall incorporate an integral elec-
trically wound spring reserve power unit, which shall power the clock mech-
anism for up to 16 hours on a power failure. The time switch shall be similar
and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished
with built-in 480-120V transformer to operate timing motor in parallel with
480 volt load. The time switch shall be Tork Model 8001U.
MOTOR
†Model # with
H.P.
†Model #
Reserve Power
Switch
Type
Amps
Rating
AC Voltage
Hz
8001
–
SPDT
24 Hour
20
3/4
120
60
8002N**
–
DPST
24 Hour
20
3/4 @ 125V
125
60
1-1/2 @ 250V
8004
–
SPDT
24 Hour
20
3/4
208-277
60††
8001U
–
SPDT
24 Hour
5
3/4
480/120 Trans.
60
8007
8007L
SPDT
7 Day Omit
20
3/4
120
60
8008
8008L
SPDT
7 Day Omit
20
3/4
208-277
60††
8007V
8007VL
SPDT
14 Day Omit
20
3/4
120
60
8042N**
–
DPST
24 Hour
20
3/4 @ 125V
208-250
60
1-1/2 @ 250V
8000 SERIES
H
120VAC
N
C
L
2
NO
NC
LOAD 2
MOTOR
LOAD 1
CLOSED WITH
TAB INWARD
CLOSED WITH
TAB OUTWARD
†24 volt in all models available on specification.
††Available in 240VAC, 50Hz **Noryl enclosure is standard. Noryl enclosure with clear Lexan
®
cover
is optional - add suffix “C” to catalog number (i.e. 8002 NC)
H
N
125VAC
C
NC
C
NC
MOTOR
LOAD 1
LOAD 2
H
208-250VAC
H
C
NC
C
NC
STARTER
COIL
OR MOTOR
MOTOR
LOAD
Model
8002N
DPST
Model
8042N
DPST
ALL SPDT
MODELS
ORDERING INFORMATION
®
LISTED
UL
®