WIRE FUNCTIONS

0. Black

0V

Negative power supply connection.

1. Brown

RANGE

Do not connect for 99999 Hour range.

Connect to 0V for 9999.9 Hour range.

Positive power supply connection.

3. Orange V-SENSE

Connect to V+to start/continue counting elapsed hours.

Connect to 0V or do not connect to read TRIP or TOTAL value without counting elapsed hours.

4. Yellow

PULSE

Normally at 0V, this output goes High (+3.3V) every 100 hour interval in TRIP mode.

5. Green

LZB

Do not connect to display leading zeros.

Connect to 0V to blank all leading zeros.

When reading is 0000.0 or 00000, leading zeros are not blanked.

6. Blue

RESET

Connect momentarily to 0V to reset the display to zero (internally connected to V+ via pull-up resistor).

7. Violet

TRIP/TOTAL

Do not connect for TOTAL mode operation. In TOTAL mode, the elapsed hour meter cannot be reset to zero.

Connect to 0V for TRIP mode operation. In TRIP mode, the elapsed hour meter can be reset to zero.

2. Red

V+

Specifications liable to change without prior warning

QM 120 ET Issue 6

September/200. Applies to QM 120 ET

APPLICATIONS

Basic 3-wire operation:

- Leading Zeros are displayed

- Timing in TOTAL mode

Open S1 to read TOTAL value

without counting hours.

- 99999 Hour range

Red

Orange

Black

0V

V+

-

Leading zeros blanked.

Close S1 to select TRIP mode.

Red

Orange

Black

0V

V+

-

9999.9 Hour range

- Leading Zeros are displayed

- Timing in TRIP mode

Red

Brown

Violet

Orange

Black

0V

V+

-

Using the PULSE O/P to drive an LED.

The LED will illuminate once after every hour.

Red

Brown

Violet

Orange

Black

Yellow

Green

Violet

S1

S1

R

LED

V+

-

0V

Hrs

TRIP

TRIP

Hrs

Hrs

DISPLAY FUNCTIONS

8888.8

The 5 digit readout displays elapsed time in hours.

This symbol is displayed when trip mode is selected (see Wire Functions above)

The 10-segment incrementing bar indicates that the module is working correctly and counting hours.

This symbol is displayed when total mode is selected (see Wire Functions above)

- - - - - - - - - -

TRIP

TOTAL

Hrs

TOTAL

TOTAL

Warning :

Do not connect the following wires to V+: RANGE, PULSE, LZB, RESET, TRIP/TOTAL, as this may

damage the meter. The user must incorporate suitable protection circuitry in applications where

the voltage to any of the meter's wires can exceed 27V d.c., including transient conditions, else

damage to the meter may occur. In particular, for applications in harsh electrical environments,

e.g. automotive, suitable external protection must be provided to protect against "load dump"

conditions, transients, etc.