Batttery replacement, Accessories and options, 1. metal part for line probe, and replacement – KYORITSU 3123A User Manual
Page 10: 2. how to use the adaptor for recorder

−
8 −
Remove the battery compartment cover by loosening the screw located
on the back of the housing case. Replace the whole battery pack. Alkaline
batteries are recommended where the instrument is used at a temperature
below the freezing point. The ordinary manganese batteries will deteriorate
below the freezing point.
5. Batttery Replacement
6-1. Metal part for Line Probe, and replacement
(
1)Tip metal parts
MODEL8252: Standard Prod (straight type, with molded parts)
MODEL8254: Straight Type Prod
MODEL8019: Pickel Type Prod (accessory)
To be used to hook the instrument.
Note:Option KEW3121A, KEW3122A
(
2)How to replace it
Turn the Line probe counterclockwise to remove the attached tip metal. Put the
tip metal you want to use to the hexagon socket and turn it to clockwise together
with the tip of probe, and tight up screws.
6-2. How to use the adaptor for recorder
MODEL8324 is the adaptor for recorder for output current measurement. Connect
it as shown in the below Fig.3.
Output is DC10mV when current of 1μA is flowing.
6. Accessories and options