beautypg.com

KROHNE IFC 110 Converter HART V0201 User Manual

Page 8

background image

KROHNE Messtechnik GmbH & Co. KG · Ludwig-Krohne-Str. 5

D-47058 Duisburg

8/15

Tel.: 0203-301 0

Fax: 0203-301 389 · e-mail: [email protected]

Supplementary Installation and Operating Instructions IFC110 HART

HC275, AMS, PDM

Attachment A

1 Process

Variables

2 Outputs/

Inputs









3 Operation











4 Test






5 Installation








6 Quit/Reset

7 Entry Code

8 HART

Variables

1 Raw Flow
2 Smoothed Flow
3 Positive Totalizer
4 Negative Totalizer
5 Totalizers’ Sum

1 Full Scale
2 Apply Full Scale
3 Damping applied to
4 Time Constant
5 Low Flow Cutoff
6 Display

7 Current Output I
8 Pulse P
9 Pulse 2 A1

Opt

10 Status A1

Opt

11 Status A2
12 Status D1
13 Status D2
14 Trip.Point 1

Opt

15 Trip.Point 2

Opt

16 Control C1
17 Control C2
18 Auto/Extern. Range

Opt

IFC110 Menu Tree HC275

KROHNE IFC110 45f30201

1 Cutoff Control
2 Cutoff ‘On’ Value
3 Cutoff ‘Off’ Value

1 Test Range Q
2 Hardware Info
3 Hardware Test
3 Sensor Limits

1 Upper Sensor Limit

Rd

2 Sensor Min Span

Rd

1 Language
2 Flowmeter

3 Zero trim
4 User Unit
5 Application
6 Hardware
7 COM 1

1 Diameter
2 Full Scale
3 Apply Full Scale
4 GK Value
5 Field Frequency
6 Line Frequency

Opt

7 Flow Direction

1 Text Volume
2 Factor Volume
3 Text Time
4 Factor Time

1 Terminal A1
2 Field Current

1 Totalizers
2 Master reset
3 Error List

Polling address

1 Manufacturer

Rd

2 Model

Rd

3 Device Id

Rd

4 Write protect

Rd

5 Tag
6 Descriptor
7 Message
8 Date
9 Sensor Serial No
10 Final Assembly No
11 Revision #’s
12 Num resp preams
13 Polling address

Designations:

submebus have identical structure and labels

Opt

Optional, dependent on device implementation / configuration

Rd

Read-only

Loc

Local HC275,

affects only HC275 views

1 Current, I
2 PV, %Range
3 Pulse P

Opt

4 Pulse P2

Opt

4 Status A1

Opt

5 Status A2
6 Status D1
7 Status D2
8 Control C1
9 Control C2

1 Application Flow
2 ADC Gain
3 Empty Pipe

Opt

4 Special Filter
5 Limit Value

Opt

6 Limit Counter

Opt

1 Display Flow
2 Display Counters
3 Display Value P
4 Display Value P2

Opt

5 Display Messages

1 Flow Units
2 Flow Format

Loc

1 Totalizer Units
2 Totalizer Format

Loc

1 Pulse P Units
2 Pulse P Format

Loc

1 Pulse P2 Units

Opt

2 Pulse P2 Format

Loc

1 Function I
2 Reverse Range
3 Reverse Value

Opt

4 I 0%
5 I 100%
6 I Max
7 I Error

1 Function P
2 Pulse Type P
3 Pulse Control P
4 Pulse Width P

Opt

5 Unit Pulse P
6 Pulse Value P

1 Function P2

Opt

2 Pulse Type P2

Opt

3 Pulse Control P2

Opt

4 Pulse Width P2

Opt

5 Unit Pulse P2

Opt

6 Pulse Value P2

Opt

1 Characteristic

Opt

2 XXX

Opt

3 YYY

Opt

1 ID-No

Rd

2 Status

Rd

1 ADC Module
2 IO Module
3 Display Module
4 RS Module

1 Stop/Resume
2 Reset Counters

1 Universal rev.

Rd

2 Field Device rev.

Rd