M10 menu tree ams – KROHNE M10 Converter HART 0201 User Manual
Page 8
KROHNE Messtechnik GmbH & Co. KG · Ludwig-Krohne-Str. 5
¨
D-47058 Duisburg
8/15
Tel.: 0203-301 0
¨
Fax: 0203-301 389 · e-mail: [email protected]
Remote Operation Instructions M10 HART
Attachment B
Loop test
M10 Menu Tree AMS
Process Variables
Status
Scan Device
-----------------------------------
Diagnostics and Test
Calibrate
-----------------------------------
Master Reset
Totalizer
-----------------------------------
Assign
Unassign
Rename
-----------------------------------
Audit Trail
Drawing Notes ...
Help ...
-----------------------------------
Clear Offline Configuration
Compare Configurations
Configuration Properties
D/A trim
-------------------------------
Calibration Management
Basic Setup
• Flow Units
• Totalizer Units
• Unit System
• Time Constant
--------------------------------
• Low Flow Cutoffcontrol
• Cufoff ‘On’ value
• Cutoff ‘Off‘ value
--------------------------------
• Contact B1
--------------------------------
• Contact B2
--------------------------------
• Contact B3
Device
Identification
• Manufacurer
• Model
• Device ID
• Universal Revision
• Field Device Revision
• Software Revision
• Hardware Revision
• Tag
• Discriptor
• Message
• Date
• Final asembly number
• Sensor seriennumber
• Production number
• Type of instrument
• Application
• Firmware Version
Designations:
Rd
– Read-only variable;
Loc
– Local AMS variable, affects only AMS faceplates and
configuration tabs and is not read/written from/to instrument.
Sensor
Sensor Limits
• Upper Sensor limit
• Lower Sensor limit
KROHNE IFC040 45e90101
Totalizer options
-------------------------------
Counter Reset
Process Input
• Flow Units
• Totalizer Units
• Full Scale
• Flow Min
• Time Constant
--------------------------------
• Low Flow Cutoffcontrol
• Cufoff ‘On’ value
• Cutoff ‘Off‘ value
--------------------------------
Application info
• Fluid
c
• Temperature
• Pressure
• Density
• Viscosity
Linearization
• Lin Table
• Config Status
• Last Table index
• Unit System
• Full Scale
• Flow Unit
--------------------------------
Linearization Table
• X0..X12
• Y0..Y12
Output
Contact B1
• Function B1
• Contact B1
• Flow Value
• Count Value
• Hysteresis Value
--------------------------------
Contact B2
• Function B2
• Contact B2
• Flow Value
• Count Value
• Hysteresis Value
--------------------------------
Contact B3
• Function B3
HART
• Polling Address
• Tag
• Device ID
• Num. of request preams
• Num. of response preams