beautypg.com

Device description, 8 electrical data – KROHNE DK 37 NEPSI Ex i User Manual

Page 8

background image

2

DEVICE DESCRIPTION

8

DK37/M8 - H250/M8

www.krohne.com

09/2013 - 4002616801 AD DK37 NEPSI Ex ia R01 en

The minimal permissible ambient temperature depends on the display and the built in limit
switches:

2.8 Electrical data

The electronic signal output may only be connected to intrinsically safe circuits. Depending on
the instrument design, the following maximum values apply per circuit:

Version DK37/M8E/..

Irrespective of the instrument design the following values are to be observed for each
intrinsically safe circuit in case of interconnection:

Version DK37/M8M/../K.

Depending on the built in limit switches the following values are to be observed for each
intrinsically safe circuit in case of interconnection:

The values specified for C

i

and L

i

also take into account the capacities and inductances of the

internal EMC filter.

Type

Electrical built in

Minimum ambient temperature

DK37/M8E/../..

Signal output 4...20 mA

-20°C / -4°F

DK37/M8M/../..

SJ2-SN

SJ2-S1N

SC2-N0

-20°C / -4°F

DK37/M8M/../..

I7S2002-N

-40°C / -40°F

U

i

30 VDC

I

i

100 mA

P

i

1000 mW

C

i

≈ 0

Li

≈ 0

U

i

16 VDC

I

i

25 mA

P

i

64 mW

Type of limit switch I7S2002-N

SC2-N0

SJ2-SN

SJ2-S1N

C

i

165 nF

45 nF

Li

150 µH

100 µH

AD_DK37_NEPSI_Ex_ia_R01_en_4002616801_PRT.book Page 8 Friday, September 13, 2013 8:50 AM