Device description, Device description 2.1 device description, 2 description code – KROHNE H250 M9 NEPSI Ex nA User Manual
Page 4
2
DEVICE DESCRIPTION
4
H250 M9
www.krohne.com
03/2013 - 4002616501 AD H250 M9 NEPSI Ex nA R01 en
Device description
2.1 Device description
Variable area flowmeters are used to measure and display volume flows of flammable and non-
flammable gases and liquids. Depending on the device version, electrical limit switches and a 4-
20 mA signal output or a Profibus PA interface can be built into the indicator part.
2.2 Description code
The safety description code * consists of the following elements:
* positions which are not needed are omitted (no blank positions)
The indicator M9S is required for Ex nA.
1 Direction of flow
H - horizontal orientation
U - vertical downwards
no identifier - standard upwards
2 Materials / versions
RR - Stainless steel
C - PTFE or PTFE/ceramics
HC - Hastelloy
Ti - Titanium
F - Sterile version (food)
3 Heating jacket version
B - with heating jacket
4 Indicator part series
M9 - Indicator M9 standard indicator
M9S - Indicator with increased protection
M9R - Indicator in stainless steel housing
M9T - Indicator in stainless steel housing with increased protection
5 High-temperature version
HT version with HT extension
6 Electrical signal output
ESK - Electronic transmitter
7 Limit switch
K1 - One limit switch
K2 - Two limit switches
8 Explosion protection
Ex - Explosion-protected equipment