DEVICE DESCRIPTION

4

H250 M9

www.krohne.com

03/2013 - 4002616501 AD H250 M9 NEPSI Ex nA R01 en

Device description

2.1 Device description

Variable area flowmeters are used to measure and display volume flows of flammable and non-
flammable gases and liquids. Depending on the device version, electrical limit switches and a 4-
20 mA signal output or a Profibus PA interface can be built into the indicator part.

2.2 Description code

The safety description code * consists of the following elements:

* positions which are not needed are omitted (no blank positions)

The indicator M9S is required for Ex nA.

1 Direction of flow

H - horizontal orientation
U - vertical downwards
no identifier - standard upwards

2 Materials / versions

RR - Stainless steel
C - PTFE or PTFE/ceramics
HC - Hastelloy
Ti - Titanium
F - Sterile version (food)

3 Heating jacket version

B - with heating jacket

4 Indicator part series

M9 - Indicator M9 standard indicator
M9S - Indicator with increased protection
M9R - Indicator in stainless steel housing
M9T - Indicator in stainless steel housing with increased protection

5 High-temperature version

HT version with HT extension

6 Electrical signal output

ESK - Electronic transmitter

7 Limit switch

K1 - One limit switch
K2 - Two limit switches

8 Explosion protection

Ex - Explosion-protected equipment