1.4
Allowable temperatures
1.4.1 Process
temperature
For applications requiring Category 1/2 G or 1/2 D equipment, the following process
temperatures are allowed as a function of the Temperature Class:
Temperature Class
Process temperature
T6
-20…+85°C
T5
-20…+100°C
T4
-20…+135°C
T3
-20…+150°C
-20…+200°C at flange temperatures
≤
150°C
and probes with distance piece
For applications requiring Category 2 G or 2 D equipment, the following process temperatures
are allowed as a function of the Temperature Class:
Temperature Class
Process temperature
T6
-50…+85°C
T5
-50…+100°C
T4
-50…+135°C
T3
-50…+150°C
-50…+200°C at flange temperatures
≤
150°C
and probes with distance piece
1.4.2 Ambient
temperature
The minimum and maximum ambient temperatures (-20…+50°C) for the electronic equipment
are independent of Temperature Class and Category.
1.4.3 Surface
temperature
For applications requiring Category 1/2 D or 2 D equipment,
- with a dust layer of
≤
5 mm,
- an ambient temperature of
≤
50°C, and
- a flange temperature of
≤
150°C,
the maximum surface temperature at any point of the measuring device shall be equal to the
process temperature, but at least 75°C.