beautypg.com

KROHNE BM 100A ATEX EN User Manual

Page 7

background image

Section 1 – Main safety-relevant characteristics

10/2001

BM 100 A ATEX

7

1.4

Allowable temperatures

1.4.1 Process

temperature

For applications requiring Category 1/2 G or 1/2 D equipment, the following process
temperatures are allowed as a function of the Temperature Class:

Temperature Class

Process temperature

T6

-20…+85°C

T5

-20…+100°C

T4

-20…+135°C

T3

-20…+150°C
-20…+200°C at flange temperatures

150°C

and probes with distance piece

For applications requiring Category 2 G or 2 D equipment, the following process temperatures
are allowed as a function of the Temperature Class:

Temperature Class

Process temperature

T6

-50…+85°C

T5

-50…+100°C

T4

-50…+135°C

T3

-50…+150°C
-50…+200°C at flange temperatures

150°C

and probes with distance piece

1.4.2 Ambient

temperature

The minimum and maximum ambient temperatures (-20…+50°C) for the electronic equipment
are independent of Temperature Class and Category.

1.4.3 Surface

temperature

For applications requiring Category 1/2 D or 2 D equipment,

- with a dust layer of

5 mm,

- an ambient temperature of

50°C, and

- a flange temperature of

150°C,

the maximum surface temperature at any point of the measuring device shall be equal to the
process temperature, but at least 75°C.