beautypg.com

KROHNE CORIMASS E P MFM 2081 EEx EN User Manual

Page 8

background image

8

Additional Instruction for Ex version MFM 2081 / 3081

(Max. 24 V DC)

V

ext

R

ext

150 mA

Fig. 3: Preferred connections to an external counter with separate power supply
(Example). For correct wiring see tables of input/output connections

(>1200 Ohm)

Fig. 4: Connection without external voltage source (Example). For correct wiring see tables
of input/output connections

Additional input/output options

No.

Option 4*

Option 5*

Option 6

(Current and RS 485)

(Current and Modbus)

(1 Current, 1 Dual phase pulse

output and input)

5

Common (-)

Common (-)

Common (-)

6

Current output 1 (+)

Current output 1 (+)

Current output 1 (+)

4

TX/RX

TX/RX

Control Input

4.1

TX/RX

TX/RX

Pulse Output A

4.2

+5V

+5V

Pulse Output B

No.

Option C

Option D

Option E

Option F

(2 Current, Pulse and

Input)

(3 Current and Pulse)

(3 Current and Input)

(3 Current and Alarm)

5

Common (-)

Common (-)

Common (-)

Common (-)

6

Current output (+) Current output 1 (+) Current output 1 (+) Current output 1 (+)

4

Current output 2 (+) Current output 2 (+) Current output 2 (+) Current output 2 (+)

4.1

Control Input

Current output 3

(+)

Current output 3

(+)

Current output 3

(+)

4.2

Pulsee Output

Pulsee output

Control Input

Status output

(passive)

The pulse output and status outputs are passive outputs.

*Refer to separate RS 485 or Modbus manual"