3 product description, 1 configuration, 2 principle of operation – KROHNE OPTISWITCH 52x0C ARV52 unpressurized EN User Manual
Page 5: 3 storage and transport
3 Product description
3.1 Configuration
The scope of delivery encompasses:
l
Lock fitting ARV 60 for OPTISWITCH 5200 C, 5250 C
vibrating level switch
l
Documentation
- this operating instructions manual
3.2 Principle of operation
The lock fitting ARV 60 is a threaded fitting and can be used
together with a level sensor in tube version (OPTISWITCH
5200 C, 5250 C). Depending on the version, the tube
extension of the sensor must have a diameter of 21.3 mm
(0.84 in):
ARV 60 cannot be used in coated tubes.
The wetted parts of the ARV 60 are made of steel (316L).
The ARV 60 must only be used in unpressurized vessels.
With the lock fittings, sensors with tube extension can be fixed
infinitely.
The terminal screws protect the tube against sliding through.
The following versions are available:
l
ø 21.3 mm - G1A or 1 NPT (SW 41)
l
ø 21.3 mm - G1½A or 1½ NPT (SW 60)
3.3 Storage and transport
Your instrument was protected by packaging during transport.
Its capacity to handle normal loads during transport is assured
by a test acc. to DIN EN 24180.
The packaging of standard instruments consists of environ-
ment-friendly, recyclable cardboard. For special versions, PE
foam or PE foil is also used. Dispose of the packaging material
via specialised recycling companies.
l
Storage and transport temperature see "Supplement –
Technical data – Ambient conditions"
l
Relative humidity 20 … 85 %
Scope of delivery
Area of application
Physical principle
Packaging
Storage and transport tempe-
rature
Lock fitting ARV 60 - unpressurised for OPTISWITCH 5200
5
Product description
30921
-EN
-050704