Layer thickness
- Enamel

approx. 0.8 mm (0.03 in)

- ECTFE

approx. 0.5 mm (approx. 0.02 in)

- PFA

approx. 0.5 mm (approx. 0.02 in)

Surface quality
- Standard

R

a

approx. 3 µm (approx. 1.18

-4

in)

- Hygienic version 3A (OPTISWITCH

5250 C)

R

a

<0.8 µm (<3.15

-5

in)

Process fittings
- Thread

G¾ A, ¾ NPT, G1 A, 1 NPT

- Flanges

DIN from DN 25, ANSI from 1"

- hygienic fittings

Bolting DN 40 PN 40, Tri-Clamp 1", Tri-Clamp

1½" PN 10, conus DN 25 PN 40, Tuchenhagen

Varivent DN 50 PN 10

High voltage test (enamel)

max. 5 KV

Gas-tight leadthrough (optional)
- leakage rate

<10

-6

mbar l/s

- pressure resistance

PN 64

- hygienic fittings

Bolting DN 40 PN 40, Tri-Clamp 1", Tri-Clamp

1½" PN 10, conus DN 25 PN 40, Tuchenhagen

Varivent DN 50 PN 10

Output variable
Output

relay output (DPDT), 2 floating spdts

Turn-on voltage
- min.

10 mV

- max.

253 V AC, 253 V DC

Switching current
- min.

10 µA

- max.

3 A AC, 1 A DC

26

OPTISWITCH 5200 C, 5250 C - with relay output

Supplement

30431

-EN