beautypg.com

KROHNE OPTISOUND 3030C 4wire EN User Manual

Page 14

background image

~200

~400x400

4

5

°

Fig. 10: Beam deflector

The ultrasonic sensor should be installed at a location where

no installations cross the ultrasonic beam.
Vessel installations such as for example, ladders, limit

switches, heating spirals, struts etc. can cause false echoes

superimposed on the useful echo. Make sure when planning

your measuring site that the ultrasonic signals have "free

access" to the measured product.
If there are existing vessel installations, a false echo storage

should be carried out during setup.
If large vessel installations such as struts or supports cause

false echoes, these can be attenuated through supplementary

measures. Small, inclined sheet metal or plastic baffles above

the installations scatter the ultrasonic signals and avoid direct

false echoes.

Fig. 11: Cover smooth profiles with deflectors

If there are agitators in the vessel, a false echo storage should

be carried out with the agitators in motion. This ensures that

the interfering reflections from the agitators are saved with the

blades in different positions.

Vessel installations

Agitators

14

OPTISOUND 3030 C - 4 ... 20 mA/HART - four-wire

Mounting

30512

-EN
-050914