ELECTRICAL CONNECTIONS

3

11

DW 18 SERIES

www.krohne.com

11/2011 - 4001528201 - AD ATEX DW181-184 R01 en

3.1 General notes

3.2 Ex c equipment

The Ex c-approved device does not have a switch option.

3.3 Ex ia equipment

3.3.1 How to connect the electrical cables

• Use the electrical connection procedure in the Handbook.
• Supply the Ex i equipment connected to the device. Use only certified intrinsically-safe

equipment.

• Connect only to separate certified, intrinsically-safe circuits. Make sure that the electrical

circuit characteristics are not more than the values that follow.

3.3.2 Maximum intrinsically-safe values for the electrical circuit

• U

i

is not given

• I

i

≤500 mA

• C

i

=0 nF

• L

i

=0 µH

Voltage is not given, but U and I must be intrinisically safe.

WARNING!

Use the applicable cable glands for the cable entry openings in the housing.

If ambient temperature >70

°

C / >158

°

F, use heat-resistant cables, cable glands and cable

entry plugs certified for continuous operation above +80

°

C / +176

°

F.

De-energize the circuit.

INFORMATION!
Cable entries are supplied on customer demand. If you supply the cable entries, this part must
have a degree of ingress protection IP≥65 (EN 60529).