2.2 Operating conditions: ambient and process temperature

The allowable ambient temperature and corresponding flange temperature range for the device
depends on the equipment category, equipment protection level (EPL) and temperature classes
marked on the nameplate.

The equipment category, equipment protection level and temperature class give the ambient
temperature and related process temperature ranges for the device.

-40°C / -40°F is the minimum ambient temperature for all application options for use in
hazardous areas.

Equipment category 1 G or EPL Ga: Ex ia devices
Equipment category 1 D or EPL Da: Ex ia devices

Equipment category 1/2 G or EPL Gb: Ex d devices
Equipment category 1/2 D or EPL Db: Ex tb devices

Equipment category 1 G: Ex c devices
Equipment category 1 D: Ex c devices

Temperature class

Maximum ambient

temperature

Maximum process

temperature

[°C]

[°F]

[°C]

[°F]

T6

+40

+104

+60

+140

T5

+40

+104

+80

+176

T4

+60

+140

+120

+248

T3

+80

+176

+150

+302

Temperature class

Maximum ambient

temperature

Maximum process

temperature

[°C]

[°F]

[°C]

[°F]

T6

+50

+122

+60

+140

T5

+50

+122

+80

+176

T4

+60

+140

+120

+248

T3

+80

+176

+150

+302

Temperature class

Maximum ambient

temperature

Maximum process

temperature

[°C]

[°F]

[°C]

[°F]

T6

+40

+104

+60

+140

T5

+40

+104

+80

+176

T4

+60

+140

+120

+248

T3

+80

+176

+150

+302