DESCRIPTION

3

5

H250 M9

www.krohne.com

06/2013 - 4000656702 MA H250-M9 SIL R03

Description

3.1 Functional principle

The flowmeter operates in accordance with the float measuring principle.

A metal cone is installed in the measuring unit H250, in which a suitably shaped float can move
freely up and down.

The flowmeter is inserted into a vertical pipeline and the medium flows through it from bottom to
top.

The guided float adjusts itself so that the buoyancy force A acting on it, the form drag W, the
weight G and the spring load S are in equilibrium (G + S = A + W).

An annular gap results which width depends on the current flow rate.

The height of the float in the measuring unit, which depends on the float, is transmitted by a
magnetic coupling and displayed on a scale.

Strong deflecting magnetic fields can lead to deviations in the measured value.

Figure 3-1: Functional principle