DESCRIPTION

3

5

H250

www.krohne.com

02/2012 - 4000656701 MA H250-M9 SIL R02

Description

3.1 Functional principle

The flowmeter operates in accordance with the float measuring principle.

A metal cone is installed in the measuring unit H250, in which a suitably shaped float can move
freely up and down.

The flowmeter is inserted into a vertical pipeline and the medium flows through it from bottom to
top.

The guided float adjusts itself so that the buoyancy force A acting on it, the form drag W and
weight G are in equilibrium (G = A + W).

An annular gap results which width depends on the current flow rate.

The height of the float in the measuring unit, which depends on the float, is transmitted by a
magnetic coupling and displayed on a scale.

Strong deflecting magnetic fields can lead to deviations in the measured value.

Figure 3-1: Functional principle

MA_H250_M9_SIL2_R02_en_656701_PRT.book Page 5 Thursday, March 1, 2012 10:26 AM