8

ANNEX

12

H250

www.krohne.com

02/2012 - 4000656701 MA H250-M9 SIL R02

Option 1:

Option 1:

Option 1:

Option 1: H250/M9 connected to a standard switching amplifier

Appropriate Isolating Switching Amplifiers:

Option 2:

Option 2:

Option 2:

Option 2: H250/M9 connected to a fail-safe switching amplifier

Appropriate Isolating Switching Amplifiers:

Type code

Technology

SC3,5-N0-Y47819-ATEX-Dub.

2-wire technology (NAMUR)

Type code

Supply voltage

Channel

Output

Ordering No.

KFA6-SR2-Ex1.W

230 VAC

1

relay

5015262000

KFA5-SR2-Ex1.W

115 VAC

1

relay

5015262100

KFD2-SR2-Ex1.W

24 VDC

1

relay

5015262200

KFA6-SR2-Ex2.W

230 VAC

2

relay

5015262300

KFA5-SR2-Ex2.W

115 VAC

2

relay

5015262400

KFD2-SR2-Ex2.W

24 VDC

2

relay

5015262500

Type code

Technology

SJ3,5-SN-ATEX

2-wire technology safety-oriented

SJ3,5-S1N-ATEX

2-wire technology safety-oriented

Type code

Supply voltage

Channel

Output

Ordering No.

KFD2-SH-Ex1

20...35 VDC

1

redundant relay

501526800

KFD2-SH-Ex1.T.OP

20...35 VDC

1

Electronic and relay

optional

KHA6-SH-Ex1

85...253 VAC

1

redundant relay

optional

MA_H250_M9_SIL2_R02_en_656701_PRT.book Page 12 Thursday, March 1, 2012 10:26 AM